2010•Physical Testing and Chemical AnalysisRequires access

ICP-AES Determination of Mn,P,Cu,Cr,Ni,Mo,V and Al in 70 Ferrotitanium

HU Jian-chun

Open publisher page 0 citations

Abstract

A method of ICP-AES determination of 8 elements,i.e.,Mn,P,Cu,Cr,Ni,Mo,V and Al,in ferrotitanium was proposed.It was found that the sample was suitably dissolved in conc.HCl(3 mL)and conc.HNO3(3 mL),and that same amount of acids should be added to the matrix metals(i.e.pure iron and pure titanium powder)in the preparation of working curves.Those spectral lines showing low detection limits and less spectral interferences were selected as the analytical spectral lines for determination of the 8 elements.By using the matrix matching method in preparation of working curves,the matrix interference was eliminated.Values of detection limit(3s/b)for the 8 elements were found in the range of 0.002-0.02 mg·L-1.Tests for accuracy and precision were made by analyzing a standard sample(YSBC 15602)for 11 determinations,results of the 8 elements found were in consistency with the known values,and values of RSD's(n=11)obtained were in the range of 0.74%-4.11%.

About this research paper

What this paper is about

A method of ICP-AES determination of 8 elements,i.e.,Mn,P,Cu,Cr,Ni,Mo,V and Al,in ferrotitanium was proposed.It was found that the sample was suitably dissolved in conc.HCl(3 mL)and conc.HNO3(3 mL),and that same amount of acids should be added to the matrix metals(i.e.pure iron and pure titanium powder)in the preparation of working curves.Those spectral lines showing low detection limits and less spectral interferences were selected as the analytical spectral lines for determination of the 8 elements.By using the matrix matching method in preparation of working curves,the matrix interference was eliminated.Values of detection limit(3s/b)for the 8 elements were found in the range of 0.002-0.02 mg·L-1.Tests for accuracy and precision were made by analyzing a standard sample(YSBC 15602)for 11 determinations,results of the 8 elements found were in consistency with the known values,and values of RSD's(n=11)obtained were in the range of 0.74%-4.11%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method of ICP-AES determination of 8 elements,i.e.,Mn,P,Cu,Cr,Ni,Mo,V and Al,in ferrotitanium was proposed.It was found that the sample was suitably dissolved in conc.HCl(3 mL)and conc.HNO3(3 mL),and that same amount of acids should be added to the matrix metals(i.e.pure iron and pure titanium powder)in the preparation of working curves.Those spectral lines showing low detection limits and less spectral interferences were selected as the analytical spectral lines for determination of the 8 elements.By using the matrix matching method in preparation of working curves,the matrix interference was eliminated.Values of detection limit(3s/b)for the 8 elements were found in the range of 0.002-0.02 mg·L-1.Tests for accuracy and precision were made by analyzing a standard sample(YSBC 15602)for 11 determinations,results of the 8 elements found were in consistency with the known values,and values of RSD's(n=11)obtained were in the range of 0.74%-4.11%.

Key concepts: Analytical Chemistry (journal), Detection limit, Standard addition, Matrix (chemical analysis), Inductively coupled plasma atomic emission spectroscopy, Materials science, Chemistry, Inductively coupled plasma

Related papers

Back to paper searchBrowse research topicsOriginal source
ICP-AES Determination of Mn,P,Cu,Cr,Ni,Mo,V and Al in 70 Ferrotitanium — Research Paper | ScholarLens