2012Unpublished venueRequires access

Volar locking compression plate combining with external fixation in treatment of the distal radius fractures of type C3 from volar and dorsal approaches

Hui He

Open publisher page 0 citations

Abstract

Objective To investigate the clinical efficacy of volar locking compression plate combining with external fixation used in treatment of the distal radius fractures of type C3 from volar and dorsal approaches.Methods 19 patients with distal radius fracture of type C3 were treated with volar locking compression plate combining with external fixation from volar and dorsal approaches.4 weeks after the operation,the external fixator was adjusted to neutral position to start rotation of the forearm exercises;6 weeks after the operation,the external fixator was removed to start function of wrist exercises.Results 19 patients were followed up range from 8 to 15 months.There were no cases with osteomyelitis,infection and traumatic arthritis in the follow-up period.The bone union time was 4~6 months.6 months after operation according to the improved Gartland-Werley grading system,the wrist function was evaluated as excellent in 14 cases,good in 3 cases and fair in 2.In relative length of distal radius,palmar tilt and ulnar deviation,there were no significant diffenences between 1 week after operation and after 6 months(P0.05),there were no significant defferences between 6 months after operation compared with the opposite side(P0.05).Conclusions Volar locking compression plate combining with external fixation is an effective treatment for the distal radius fractures of type C3 from volar and dorsal approaches.

About this research paper

What this paper is about

Objective To investigate the clinical efficacy of volar locking compression plate combining with external fixation used in treatment of the distal radius fractures of type C3 from volar and dorsal approaches.Methods 19 patients with distal radius fracture of type C3 were treated with volar locking compression plate combining with external fixation from volar and dorsal approaches.4 weeks after the operation,the external fixator was adjusted to neutral position to start rotation of the forearm exercises;6 weeks after the operation,the external fixator was removed to start function of wrist exercises.Results 19 patients were followed up range from 8 to 15 months.There were no cases with osteomyelitis,infection and traumatic arthritis in the follow-up period.The bone union time was 4~6 months.6 months after operation according to the improved Gartland-Werley grading system,the wrist function was evaluated as excellent in 14 cases,good in 3 cases and fair in 2.In relative length of distal radius,palmar tilt and ulnar deviation,there were no significant diffenences between 1 week after operation and after 6 months(P0.05),there were no significant defferences between 6 months after operation compared with the opposite side(P0.05).Conclusions Volar locking compression plate combining with external fixation is an effective treatment for the distal radius fractures of type C3 from volar and dorsal approaches.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investigate the clinical efficacy of volar locking compression plate combining with external fixation used in treatment of the distal radius fractures of type C3 from volar and dorsal approaches.Methods 19 patients with distal radius fracture of type C3 were treated with volar locking compression plate combining with external fixation from volar and dorsal approaches.4 weeks after the operation,the external fixator was adjusted to neutral position to start rotation of the forearm exercises;6 weeks after the operation,the external fixator was removed to start function of wrist exercises.Results 19 patients were followed up range from 8 to 15 months.There were no cases with osteomyelitis,infection and traumatic arthritis in the follow-up period.The bone union time was 4~6 months.6 months after operation according to the improved Gartland-Werley grading system,the wrist function was evaluated as excellent in 14 cases,good in 3 cases and fair in 2.In relative length of distal radius,palmar tilt and ulnar deviation,there were no significant diffenences between 1 week after operation and after 6 months(P0.05),there were no significant defferences between 6 months after operation compared with the opposite side(P0.05).Conclusions Volar locking compression plate combining with external fixation is an effective treatment for the distal radius fractures of type C3 from volar and dorsal approaches.

Key concepts: Medicine, Wrist, External fixation, Fixation (population genetics), Surgery, Ulnar deviation, Forearm, Dorsum

Related papers

Back to paper searchBrowse research topicsOriginal source
Volar locking compression plate combining with external fixation in treatment of the distal radius fractures of type C3 from volar and dorsal approaches — Research Paper | ScholarLens