2013Unpublished venueRequires access

Volar locking plate combined with external fixator in the treatment of unstable distal radius type C fractures

Ji Cao

Open publisher page 0 citations

Abstract

Objective To investigate the effect of volar locking plate combined with external fixator in the treatment of unstable distal radius type C fractures. Methods 24 patients with unstable distal radius type C fractures were treated by volar locking plate combined with external fixator. Results 22 cases were followed up for 6 ~ 29 months. Acorrding to Lidstrom scoring criteria,image evaluation were excellent in 12 cases,good in 7,and fair in 3. According to Cooney functional evaluation standard,the function evaluation of the wrist joint were excellent in 17 cases,good in 3,and fair in 2. No serious complications were found. Conclusions The volar locking plate combined with external fixator in the treatment of unstable distal radius type C fractures can earlier recover and have satisfactory function.

About this research paper

What this paper is about

Objective To investigate the effect of volar locking plate combined with external fixator in the treatment of unstable distal radius type C fractures. Methods 24 patients with unstable distal radius type C fractures were treated by volar locking plate combined with external fixator. Results 22 cases were followed up for 6 ~ 29 months. Acorrding to Lidstrom scoring criteria,image evaluation were excellent in 12 cases,good in 7,and fair in 3. According to Cooney functional evaluation standard,the function evaluation of the wrist joint were excellent in 17 cases,good in 3,and fair in 2. No serious complications were found. Conclusions The volar locking plate combined with external fixator in the treatment of unstable distal radius type C fractures can earlier recover and have satisfactory function.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investigate the effect of volar locking plate combined with external fixator in the treatment of unstable distal radius type C fractures. Methods 24 patients with unstable distal radius type C fractures were treated by volar locking plate combined with external fixator. Results 22 cases were followed up for 6 ~ 29 months. Acorrding to Lidstrom scoring criteria,image evaluation were excellent in 12 cases,good in 7,and fair in 3. According to Cooney functional evaluation standard,the function evaluation of the wrist joint were excellent in 17 cases,good in 3,and fair in 2. No serious complications were found. Conclusions The volar locking plate combined with external fixator in the treatment of unstable distal radius type C fractures can earlier recover and have satisfactory function.

Key concepts: Medicine, External fixator, Wrist, RADIUS, Surgery, Distal radius fracture, Orthodontics, Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
Volar locking plate combined with external fixator in the treatment of unstable distal radius type C fractures — Research Paper | ScholarLens