Determination of acrylonitrile monomer and vinyl chloride in clothing by capillary gas chromatography with AutoHS headspace sampler
Zhang Xu-long
Abstract
Zhang Xu-long
Abstract
Objective:An analytical method has been described for the quantitative determination of acrylonitrile monomer and vinyl chloride in clothing by.Methods: Headspace capillary gas chromatography has been developed.The acrylonitrile and chloroethlene monomer were isolated from a standard solution or samples using a headspace system,then quantified by GC-FID.The experimental conditions of headspace and GC were optimized.External standards were used for quantitative determination.DB-624 capillary column and flame ionization detector(FID) were employed.Results: Under the optimal condition,linear responses were obtained for acrylonitrile and chloroethlene monomer in their respective concentration ranges(R1=0.99987,n1=5;R2=0.99990,n2=5).The average recoveries were 96.6%~99.2% for acrylonitrile monomer and 90.0%~110.0% for chloroethlene monomer,and relative standard deviations were 4.25% in three levels respectively.The limits of detection of acrylonitrile and chloroethlene monomer were 0.50 μg/g and 0.25 μg/g,respectively.Conclusion: The method was simple and quick.It was suitable for the determination of acrylonitrile monomer and vinyl chloride in exported clothing.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:An analytical method has been described for the quantitative determination of acrylonitrile monomer and vinyl chloride in clothing by.Methods: Headspace capillary gas chromatography has been developed.The acrylonitrile and chloroethlene monomer were isolated from a standard solution or samples using a headspace system,then quantified by GC-FID.The experimental conditions of headspace and GC were optimized.External standards were used for quantitative determination.DB-624 capillary column and flame ionization detector(FID) were employed.Results: Under the optimal condition,linear responses were obtained for acrylonitrile and chloroethlene monomer in their respective concentration ranges(R1=0.99987,n1=5;R2=0.99990,n2=5).The average recoveries were 96.6%~99.2% for acrylonitrile monomer and 90.0%~110.0% for chloroethlene monomer,and relative standard deviations were 4.25% in three levels respectively.The limits of detection of acrylonitrile and chloroethlene monomer were 0.50 μg/g and 0.25 μg/g,respectively.Conclusion: The method was simple and quick.It was suitable for the determination of acrylonitrile monomer and vinyl chloride in exported clothing.
Key concepts: Acrylonitrile, Monomer, Vinyl chloride, Gas chromatography, Flame ionization detector, Chemistry, Chromatography, Detection limit