Clinical application of percutaneous puncture biopsy with 20G automatic biopsy device guided by 18G coaxial puncture needle (a report of 45 cases)
Jian Zhang
Abstract
Jian Zhang
Abstract
Objective:To evaluate the effectiveness of percutaneous puncture biopsy with 20G automatic biopsy device guided by 18G coaxial needle.Methods:45 patients, 29 males and 16 females,age range 20~83 years,were performed percutaneous puncture biopsy with 20G automatic biopsy device guided by 18G coaxial needle under CT-guidance.The biopsy sites included lung (18 cases),liver (16 cases),thyroid gland (2 cases), mediastinum (3 cases),deep soft tissue of the neck(2 cases),pleura (3 cases) and peritoneal cavity (1 case). Results:In total 47 biopsy procedures were performed,the success puncture rate was 100%;the success biopsy rate was 93.3%(42/45),the biopsy diagnostic accuracy was 93.3%(42/45);the success biopsy rate and biopsy diagnostic accuracy of liver was 100%;the success biopsy rate of lung was 88.9%(16/18),the biopsy diagnostic accuracy was 87.5%(14/16).The total rate of complication was 8.9%(4/45),there were 3 cases with pneumothorax and one case with emptysis. Conclusion:Percutaneous puncture biopsy with 20G automatic biopsy device guided by 18G coaxial needle is a safe,effective and easy procedure of biopsy with coaxial puncture.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To evaluate the effectiveness of percutaneous puncture biopsy with 20G automatic biopsy device guided by 18G coaxial needle.Methods:45 patients, 29 males and 16 females,age range 20~83 years,were performed percutaneous puncture biopsy with 20G automatic biopsy device guided by 18G coaxial needle under CT-guidance.The biopsy sites included lung (18 cases),liver (16 cases),thyroid gland (2 cases), mediastinum (3 cases),deep soft tissue of the neck(2 cases),pleura (3 cases) and peritoneal cavity (1 case). Results:In total 47 biopsy procedures were performed,the success puncture rate was 100%;the success biopsy rate was 93.3%(42/45),the biopsy diagnostic accuracy was 93.3%(42/45);the success biopsy rate and biopsy diagnostic accuracy of liver was 100%;the success biopsy rate of lung was 88.9%(16/18),the biopsy diagnostic accuracy was 87.5%(14/16).The total rate of complication was 8.9%(4/45),there were 3 cases with pneumothorax and one case with emptysis. Conclusion:Percutaneous puncture biopsy with 20G automatic biopsy device guided by 18G coaxial needle is a safe,effective and easy procedure of biopsy with coaxial puncture.
Key concepts: Medicine, Biopsy, Radiology, Pneumothorax, Percutaneous, Surgery, Mediastinum