2004•PubMedRequires access

[Finite element analysis of changes in femoral stresses after elite total hip arthroplasty].

Rongxin He, Yin-Miao Luo, Shigui Yan, Haobo Wu

Open publisher page 2 citations

Abstract

OBJECTIVE: To determine the variation in femoral stress after insertion of Elite cemented femoral prosthesis. METHODS: Three-dimentional finite element models of the normal human femur and Elite femoral prosthesis were developed through CT scan. With the application of hip joint loading, quantitatively measure stress changes of an intact femur with corresponding femur inserted with Elite implants were measured. RESULTS: Compared with intact femur, insertion of Elite implants into the femoral canal decreased the proximal femoral stresses level, especially in calcar femoral, femur wall and tuberositas. However, the stress in the prosthesis distal end. CONCLUSION: Insertion of Elite implants induced significant stress shielding in the proximal femur, especially at calcar femoral, femur wall and tuberositas. However, stress concentrates in the prosthesis distal end.

About this research paper

What this paper is about

OBJECTIVE: To determine the variation in femoral stress after insertion of Elite cemented femoral prosthesis. METHODS: Three-dimentional finite element models of the normal human femur and Elite femoral prosthesis were developed through CT scan. With the application of hip joint loading, quantitatively measure stress changes of an intact femur with corresponding femur inserted with Elite implants were measured. RESULTS: Compared with intact femur, insertion of Elite implants into the femoral canal decreased the proximal femoral stresses level, especially in calcar femoral, femur wall and tuberositas. However, the stress in the prosthesis distal end. CONCLUSION: Insertion of Elite implants induced significant stress shielding in the proximal femur, especially at calcar femoral, femur wall and tuberositas. However, stress concentrates in the prosthesis distal end.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To determine the variation in femoral stress after insertion of Elite cemented femoral prosthesis. METHODS: Three-dimentional finite element models of the normal human femur and Elite femoral prosthesis were developed through CT scan. With the application of hip joint loading, quantitatively measure stress changes of an intact femur with corresponding femur inserted with Elite implants were measured. RESULTS: Compared with intact femur, insertion of Elite implants into the femoral canal decreased the proximal femoral stresses level, especially in calcar femoral, femur wall and tuberositas. However, the stress in the prosthesis distal end. CONCLUSION: Insertion of Elite implants induced significant stress shielding in the proximal femur, especially at calcar femoral, femur wall and tuberositas. However, stress concentrates in the prosthesis distal end.

Key concepts: Femur, Calcar, Stress shielding, Prosthesis, Medicine, Femoral canal, Orthodontics, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
[Finite element analysis of changes in femoral stresses after elite total hip arthroplasty]. — Research Paper | ScholarLens