Abstract

BACKGROUND: The aim of this study was to develop and perform the 3D finite element analysis of a femoral head interior supporting device (FHISD). MATERIAL AND METHODS: The 3D finite element model was developed to analyze the surface load of femoral head and analyze the stress and strain of the femoral neck, using the normal femoral neck, decompressed bone graft, and FHISD-implanted bone graft models. RESULTS: The stress in the normal model concentrated around the femoral calcar, with displacement of 0.3556±0.1294 mm. In the decompressed bone graft model, the stress concentrated on the femur calcar and top and lateral sides of femoral head, with the displacement larger than the normal (0.4163±0.1310 mm). In the FHISD-implanted bone graft model, the stress concentrated on the segment below the lesser trochanter superior to the femur, with smaller displacement than the normal (0.1856±0.0118 mm). CONCLUSIONS: FHISD could effectively maintain the biomechanical properties of the femoral neck.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: The aim of this study was to develop and perform the 3D finite element analysis of a femoral head interior supporting device (FHISD). MATERIAL AND METHODS: The 3D finite element model was developed to analyze the surface load of femoral head and analyze the stress and strain of the femoral neck, using the normal femoral neck, decompressed bone graft, and FHISD-implanted bone graft models. RESULTS: The stress in the normal model concentrated around the femoral calcar, with displacement of 0.3556±0.1294 mm. In the decompressed bone graft model, the stress concentrated on the femur calcar and top and lateral sides of femoral head, with the displacement larger than the normal (0.4163±0.1310 mm). In the FHISD-implanted bone graft model, the stress concentrated on the segment below the lesser trochanter superior to the femur, with smaller displacement than the normal (0.1856±0.0118 mm). CONCLUSIONS: FHISD could effectively maintain the biomechanical properties of the femoral neck.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The aim of this study was to develop and perform the 3D finite element analysis of a femoral head interior supporting device (FHISD). MATERIAL AND METHODS: The 3D finite element model was developed to analyze the surface load of femoral head and analyze the stress and strain of the femoral neck, using the normal femoral neck, decompressed bone graft, and FHISD-implanted bone graft models. RESULTS: The stress in the normal model concentrated around the femoral calcar, with displacement of 0.3556±0.1294 mm. In the decompressed bone graft model, the stress concentrated on the femur calcar and top and lateral sides of femoral head, with the displacement larger than the normal (0.4163±0.1310 mm). In the FHISD-implanted bone graft model, the stress concentrated on the segment below the lesser trochanter superior to the femur, with smaller displacement than the normal (0.1856±0.0118 mm). CONCLUSIONS: FHISD could effectively maintain the biomechanical properties of the femoral neck.

Key concepts: Femoral head, Calcar, Femoral neck, Femur, Trochanter, Finite element method, Displacement (psychology), Avascular necrosis

Related papers