Determination of Chlorobromoisocyanuric Acid by HPLC
Pan Jin-j
Abstract
Pan Jin-j
Abstract
The quantitative analytical method was developed for chlorobromoisocyanuric acid by HPLC with C18 coloumn, UV 215 nm detection, methanol and water and acetic acid (15+85+0.1) as mobile phase. The results showed that the coefficient of variation was 0.44%. The average recovery was 98% to 102%.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The quantitative analytical method was developed for chlorobromoisocyanuric acid by HPLC with C18 coloumn, UV 215 nm detection, methanol and water and acetic acid (15+85+0.1) as mobile phase. The results showed that the coefficient of variation was 0.44%. The average recovery was 98% to 102%.