Location of partial discharges fault in transformer winding

Ju Ping

Open publisher page 0 citations

Abstract

Frequency response analysis can be used to examine distortion fault in transformer windings,but can't perform partial discharge Location. Based on frequency response analysis, the simulative circuit of transformer's winding was analyzed in this paper.According to the pure capacitive characteristic in current frequency range in transformer winding,a new method was given to realize locate the partial discharges fault in transformer winding.The method is proved to be effective by simulative experimentation.

About this research paper

What this paper is about

Frequency response analysis can be used to examine distortion fault in transformer windings,but can't perform partial discharge Location. Based on frequency response analysis, the simulative circuit of transformer's winding was analyzed in this paper.According to the pure capacitive characteristic in current frequency range in transformer winding,a new method was given to realize locate the partial discharges fault in transformer winding.The method is proved to be effective by simulative experimentation.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Frequency response analysis can be used to examine distortion fault in transformer windings,but can't perform partial discharge Location. Based on frequency response analysis, the simulative circuit of transformer's winding was analyzed in this paper.According to the pure capacitive characteristic in current frequency range in transformer winding,a new method was given to realize locate the partial discharges fault in transformer winding.The method is proved to be effective by simulative experimentation.

Key concepts: Partial discharge, Autotransformer, Rotary variable differential transformer, Delta-wye transformer, Transformer, Electromagnetic coil, Energy efficient transformer, Distribution transformer