2011Water Resources and PowerRequires access

Fault Analysis of Transformer Winding Based on Frequency Response Method

Jianlin Zhu

Open publisher page 0 citations

Abstract

To detect the deformation faults of transformer winding,this paper describes method and wiring of measuring transformer winding deformation with TFRC-Ⅱ type power transformer winding frequency response tester.The transformer winding fault is measured and the relationship between winding deformation and frequency response is analyzed.Phase B frequency spectrogram of the transformer appears difference in low-frequency stage,which is caused by winding inductance variation leading to integral deformation.The analysis result is verified by disassembling inspection of transformer in manufactory.The results show that the frequency response method is feasible and effective.

About this research paper

What this paper is about

To detect the deformation faults of transformer winding,this paper describes method and wiring of measuring transformer winding deformation with TFRC-Ⅱ type power transformer winding frequency response tester.The transformer winding fault is measured and the relationship between winding deformation and frequency response is analyzed.Phase B frequency spectrogram of the transformer appears difference in low-frequency stage,which is caused by winding inductance variation leading to integral deformation.The analysis result is verified by disassembling inspection of transformer in manufactory.The results show that the frequency response method is feasible and effective.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To detect the deformation faults of transformer winding,this paper describes method and wiring of measuring transformer winding deformation with TFRC-Ⅱ type power transformer winding frequency response tester.The transformer winding fault is measured and the relationship between winding deformation and frequency response is analyzed.Phase B frequency spectrogram of the transformer appears difference in low-frequency stage,which is caused by winding inductance variation leading to integral deformation.The analysis result is verified by disassembling inspection of transformer in manufactory.The results show that the frequency response method is feasible and effective.

Key concepts: Leakage inductance, Rotary variable differential transformer, Linear variable differential transformer, Transformer, Delta-wye transformer, Distribution transformer, Autotransformer, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Fault Analysis of Transformer Winding Based on Frequency Response Method — Research Paper | ScholarLens