2012Zhongguo shiyan fangjixue zazhiRequires access

Establishment of RP-LC/ESI-MS Combained with HILIC/ESI-MS Method for Research of Metabonomics of Rat Urine

高晓燕, Bai Yu-jing Gao Xiao-yan, 白玉静

Open publisher page 0 citations

Abstract

Objective:To establish a RP-LC/ESI-MS combined with HILIC/ESI-MS method for the research of metabonomics.Method: For RP-LC/ESI-MS,the assay was conducted on a Prevail C18(4.6 mm×250 mm,5 μm).The mobile phase A was 10 mmol · L-1 ammonium formate(adjusted to pH 4 with formic acid) in water,B was acetonitrile-formic acid(99.9∶0.1).A gradient elution mode composed of A and B was used as the mobile phase.For HILIC/ESI-MS,the assay was conducted on a Alltima HP HILIC(2.1 mm×150 mm,3 μm).The mobile phase A was 10 mmol · L-1 ammonium formate(adjusted to pH 4 with formic acid) in water,B was acetonitrile-formic acid(99.9∶0.1).A gradient elution mode composed of A and B was also used as the mobile phase.Electrospray ionization(ESI) in the positive and negative ion mode was used as the ionization source.Nitrogen was used as the nebulizer gas and was maintained at a flow of 11.0 L · min-1 with a nebulizer pressure of 50.0 psi.The fragmentor voltage was set at 275.8 V.Mass spectra were recorded covering m/z 15-2200.Result: Endogenous compounds with different polarity in rat urine could be detected by using RP-LC/ESI-MS and HILIC/ESI-MS.Conclusion: This method could offer a reference for metabonomics study.

About this research paper

What this paper is about

Objective:To establish a RP-LC/ESI-MS combined with HILIC/ESI-MS method for the research of metabonomics.Method: For RP-LC/ESI-MS,the assay was conducted on a Prevail C18(4.6 mm×250 mm,5 μm).The mobile phase A was 10 mmol · L-1 ammonium formate(adjusted to pH 4 with formic acid) in water,B was acetonitrile-formic acid(99.9∶0.1).A gradient elution mode composed of A and B was used as the mobile phase.For HILIC/ESI-MS,the assay was conducted on a Alltima HP HILIC(2.1 mm×150 mm,3 μm).The mobile phase A was 10 mmol · L-1 ammonium formate(adjusted to pH 4 with formic acid) in water,B was acetonitrile-formic acid(99.9∶0.1).A gradient elution mode composed of A and B was also used as the mobile phase.Electrospray ionization(ESI) in the positive and negative ion mode was used as the ionization source.Nitrogen was used as the nebulizer gas and was maintained at a flow of 11.0 L · min-1 with a nebulizer pressure of 50.0 psi.The fragmentor voltage was set at 275.8 V.Mass spectra were recorded covering m/z 15-2200.Result: Endogenous compounds with different polarity in rat urine could be detected by using RP-LC/ESI-MS and HILIC/ESI-MS.Conclusion: This method could offer a reference for metabonomics study.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish a RP-LC/ESI-MS combined with HILIC/ESI-MS method for the research of metabonomics.Method: For RP-LC/ESI-MS,the assay was conducted on a Prevail C18(4.6 mm×250 mm,5 μm).The mobile phase A was 10 mmol · L-1 ammonium formate(adjusted to pH 4 with formic acid) in water,B was acetonitrile-formic acid(99.9∶0.1).A gradient elution mode composed of A and B was used as the mobile phase.For HILIC/ESI-MS,the assay was conducted on a Alltima HP HILIC(2.1 mm×150 mm,3 μm).The mobile phase A was 10 mmol · L-1 ammonium formate(adjusted to pH 4 with formic acid) in water,B was acetonitrile-formic acid(99.9∶0.1).A gradient elution mode composed of A and B was also used as the mobile phase.Electrospray ionization(ESI) in the positive and negative ion mode was used as the ionization source.Nitrogen was used as the nebulizer gas and was maintained at a flow of 11.0 L · min-1 with a nebulizer pressure of 50.0 psi.The fragmentor voltage was set at 275.8 V.Mass spectra were recorded covering m/z 15-2200.Result: Endogenous compounds with different polarity in rat urine could be detected by using RP-LC/ESI-MS and HILIC/ESI-MS.Conclusion: This method could offer a reference for metabonomics study.

Key concepts: Chemistry, Ammonium formate, Hydrophilic interaction chromatography, Formic acid, Chromatography, Electrospray ionization, Acetonitrile, Mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Establishment of RP-LC/ESI-MS Combained with HILIC/ESI-MS Method for Research of Metabonomics of Rat Urine — Research Paper | ScholarLens