2005Biomedical ChromatographyRequires access

Development of an electrospray ionization mass spectrometric method for the quantification of theophylline in horse serum

Francis Beaudry, Jean‐Pierre Lavoie, Pascal Vachon

Open publisher page 10 citations

Abstract

A rapid and selective method has been developed for the determination of theophylline in horse serum by LC-ESI/MS/MS. The analytical method includes a protein precipitation extraction for sample preparation, liquid chromatography separation technique and ionspray tandem mass spectrometry. The drug was extracted from serum using a protein precipitation with acetonitrile and the supernatants were analyzed using an LC-ESI/MS/MS instrument. The chromatography was performed using a 50 x 2.1 mm C(8) analytical column and an isocratic mobile phase composes of 60:40 acetonitrile-0.5% formic acid in water with a flow rate fixed at 350 microL/min. A linear (weighted 1/concentration) relationship was used to perform the calibration over an analytical range of 0.1-20 ppm. The intra-batch precision and accuracy at LLOQ, medium and high concentration were 11.7, 6.9 and 5.4% and 95.8, 107.8 and 95.8%, respectively, and the inter-batch precision and accuracy at LLOQ, medium and high concentration were 10.4, 7.9 and 7.3% and 97.3, 105.2 and 95.9%, respectively. This LC-ESI/MS/MS method for the determination of theophylline in horse serum has been proved to within generally accepted criteria used for bioanalytical assay and was used successfully during clinical investigation.

About this research paper

What this paper is about

A rapid and selective method has been developed for the determination of theophylline in horse serum by LC-ESI/MS/MS. The analytical method includes a protein precipitation extraction for sample preparation, liquid chromatography separation technique and ionspray tandem mass spectrometry. The drug was extracted from serum using a protein precipitation with acetonitrile and the supernatants were analyzed using an LC-ESI/MS/MS instrument. The chromatography was performed using a 50 x 2.1 mm C(8) analytical column and an isocratic mobile phase composes of 60:40 acetonitrile-0.5% formic acid in water with a flow rate fixed at 350 microL/min. A linear (weighted 1/concentration) relationship was used to perform the calibration over an analytical range of 0.1-20 ppm. The intra-batch precision and accuracy at LLOQ, medium and high concentration were 11.7, 6.9 and 5.4% and 95.8, 107.8 and 95.8%, respectively, and the inter-batch precision and accuracy at LLOQ, medium and high concentration were 10.4, 7.9 and 7.3% and 97.3, 105.2 and 95.9%, respectively. This LC-ESI/MS/MS method for the determination of theophylline in horse serum has been proved to within generally accepted criteria used for bioanalytical assay and was used successfully during clinical investigation.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A rapid and selective method has been developed for the determination of theophylline in horse serum by LC-ESI/MS/MS. The analytical method includes a protein precipitation extraction for sample preparation, liquid chromatography separation technique and ionspray tandem mass spectrometry. The drug was extracted from serum using a protein precipitation with acetonitrile and the supernatants were analyzed using an LC-ESI/MS/MS instrument. The chromatography was performed using a 50 x 2.1 mm C(8) analytical column and an isocratic mobile phase composes of 60:40 acetonitrile-0.5% formic acid in water with a flow rate fixed at 350 microL/min. A linear (weighted 1/concentration) relationship was used to perform the calibration over an analytical range of 0.1-20 ppm. The intra-batch precision and accuracy at LLOQ, medium and high concentration were 11.7, 6.9 and 5.4% and 95.8, 107.8 and 95.8%, respectively, and the inter-batch precision and accuracy at LLOQ, medium and high concentration were 10.4, 7.9 and 7.3% and 97.3, 105.2 and 95.9%, respectively. This LC-ESI/MS/MS method for the determination of theophylline in horse serum has been proved to within generally accepted criteria used for bioanalytical assay and was used successfully during clinical investigation.

Key concepts: Chromatography, Chemistry, Protein precipitation, Bioanalysis, Electrospray ionization, Formic acid, Theophylline, Mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Development of an electrospray ionization mass spectrometric method for the quantification of theophylline in horse serum — Research Paper | ScholarLens