Pulse Water-lifting Aeration Bio-contact Oxidation Process for Purification of Micro-polluted Water
Zhang Qing-lin
Abstract
Zhang Qing-lin
Abstract
A pulse aeration bio-contact oxidation process was used to treat urban riverway water in lab-scale test.The optimal process parameters are as follows;the aeration intensity is4m~3/(m~2 ? h), the HRT is 2 h,the ratio of non-aeration to aeration is 6:4 to 8:2,and the aeration period is equal to or less than 2 min.The average removal rates of NH_4~+- N and COD——(Mn) are 78.30%to 93.51%and 21.12%to 24.29%respectively.The biomass on bio-media is 265.53 to 938.63 nmol/m~3.The effect of pulse aeration bio-contact oxidation process is better than that of continuous aeration bio-contact oxidation process.The pulse aeration bio-contact oxidation process saves 60%to 80%air volume compared with continuous aeration bio-contact oxidation process.A pulse water-lifting aeration in-situ water quality purification device was developed by combining water-lifting aeration with biological contact oxidation. The pilot study results show that the average removal rates of NH——4~+- N,TN and COD——(Mn) are 55.13%, 18%and 10%respectively when the water temperature is less than 15℃.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A pulse aeration bio-contact oxidation process was used to treat urban riverway water in lab-scale test.The optimal process parameters are as follows;the aeration intensity is4m~3/(m~2 ? h), the HRT is 2 h,the ratio of non-aeration to aeration is 6:4 to 8:2,and the aeration period is equal to or less than 2 min.The average removal rates of NH_4~+- N and COD——(Mn) are 78.30%to 93.51%and 21.12%to 24.29%respectively.The biomass on bio-media is 265.53 to 938.63 nmol/m~3.The effect of pulse aeration bio-contact oxidation process is better than that of continuous aeration bio-contact oxidation process.The pulse aeration bio-contact oxidation process saves 60%to 80%air volume compared with continuous aeration bio-contact oxidation process.A pulse water-lifting aeration in-situ water quality purification device was developed by combining water-lifting aeration with biological contact oxidation. The pilot study results show that the average removal rates of NH——4~+- N,TN and COD——(Mn) are 55.13%, 18%and 10%respectively when the water temperature is less than 15℃.
Key concepts: Aeration, Volume (thermodynamics), Pulp and paper industry, Chemistry, Environmental engineering, Oxidation process, Water quality, Environmental science