Research on the HPLC Analysis on 15% Abamectin·Chlorpyrifos EW
Hongying Xia
Abstract
Hongying Xia
Abstract
[Objective] The purpose was to provide scientific basis for formulating the quality standard of 15% abamectin·chlorpyrifos EW.[Method] The contents of abamectin and chlorpyrifos in 15% abamectin·chlorpyrifos EW were determined and analyzed by HPLC.[Result] The concn.-peak area regression equations of abamectin and chlorpyrifos in the control solutions were Y=762.90X+15.84 and Y=727.94X+18.91 resp.and they had good linear relationship in the range of 10.0-100.0 μg/ml.In precision test,the RSDs of chlorpyrifos and abamectin were 0.5% and 0.7% resp.In repeatability experiment,the RSDs of chlorpyrifos and abamectin were 0.9% and 0.5% resp.The average recoveries of chlorpyrifos and abamectin were 96.06% and 96.31% resp.and both of their minimal detection limits were 0.32 μg/ml.The contents of abamectin in 15% abamectin·chlorpyrifos EW stored by heat-treated storage and normal storage were 12.54% and 12.81% resp.and that of chlorpyrifos were 0.231% and 0.235% resp.[Conclusion] This method had high accuracy,strong specificity and good sensitivity and stability and its determination results were reliable.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
[Objective] The purpose was to provide scientific basis for formulating the quality standard of 15% abamectin·chlorpyrifos EW.[Method] The contents of abamectin and chlorpyrifos in 15% abamectin·chlorpyrifos EW were determined and analyzed by HPLC.[Result] The concn.-peak area regression equations of abamectin and chlorpyrifos in the control solutions were Y=762.90X+15.84 and Y=727.94X+18.91 resp.and they had good linear relationship in the range of 10.0-100.0 μg/ml.In precision test,the RSDs of chlorpyrifos and abamectin were 0.5% and 0.7% resp.In repeatability experiment,the RSDs of chlorpyrifos and abamectin were 0.9% and 0.5% resp.The average recoveries of chlorpyrifos and abamectin were 96.06% and 96.31% resp.and both of their minimal detection limits were 0.32 μg/ml.The contents of abamectin in 15% abamectin·chlorpyrifos EW stored by heat-treated storage and normal storage were 12.54% and 12.81% resp.and that of chlorpyrifos were 0.231% and 0.235% resp.[Conclusion] This method had high accuracy,strong specificity and good sensitivity and stability and its determination results were reliable.
Key concepts: Abamectin, Chlorpyrifos, Repeatability, Chemistry, Toxicology, Chromatography, Mathematics, Pesticide