2005Unpublished venueRequires access

Determination of trace cadmium in geosamles by graphite furnace atomic absorption spectrometry with slurry sampling

Ai Jun

Open publisher page 0 citations

Abstract

A method for the determination of trace cadmium in geosamples by graphite fuenace atomic absorption spectrometry(GFAAS) with slurry sampling has been presented.The influence of GAAS operation conditions,matrix modifiers and slurry stability agents have been studied.The liner range for determination of cadmium was 0~4.0 μg·L~(-1).Experimental condition limit was 2.1 pg·g~(-1),the raletive standard deviation was less than 5.5% (RSD,n=4) and the recovery rate was 95%~99%.The proposed method was rapid,simple and accurate.It has been applied to determine trace cadmium in national standard samples with satisfactory results.

About this research paper

What this paper is about

A method for the determination of trace cadmium in geosamples by graphite fuenace atomic absorption spectrometry(GFAAS) with slurry sampling has been presented.The influence of GAAS operation conditions,matrix modifiers and slurry stability agents have been studied.The liner range for determination of cadmium was 0~4.0 μg·L~(-1).Experimental condition limit was 2.1 pg·g~(-1),the raletive standard deviation was less than 5.5% (RSD,n=4) and the recovery rate was 95%~99%.The proposed method was rapid,simple and accurate.It has been applied to determine trace cadmium in national standard samples with satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for the determination of trace cadmium in geosamples by graphite fuenace atomic absorption spectrometry(GFAAS) with slurry sampling has been presented.The influence of GAAS operation conditions,matrix modifiers and slurry stability agents have been studied.The liner range for determination of cadmium was 0~4.0 μg·L~(-1).Experimental condition limit was 2.1 pg·g~(-1),the raletive standard deviation was less than 5.5% (RSD,n=4) and the recovery rate was 95%~99%.The proposed method was rapid,simple and accurate.It has been applied to determine trace cadmium in national standard samples with satisfactory results.

Key concepts: Slurry, Graphite furnace atomic absorption, Cadmium, Detection limit, Analytical Chemistry (journal), Atomic absorption spectroscopy, Matrix (chemical analysis), Graphite

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of trace cadmium in geosamles by graphite furnace atomic absorption spectrometry with slurry sampling — Research Paper | ScholarLens