2012•Zhongguo yaofangRequires access

Determination of Residual Acetaldehyde in Oral Liquid PET Bottle by Headspace Gas Chromatography

Lin Li

Open publisher page 0 citations

Abstract

OBJECTIVE:To establish the method for determination of residual acetaldehyde in oral liquid PET bottle. METHODS:Headspace gas chromatography was adopted. The determination was performed on DB-FFAP capillary column. FID detector was used with injector temperature of 200 ℃ and detector temperature of 200 ℃ using nitrogen as carrier gas. The equilibrium temperature of headspace sampling was set at 70 ℃ with equilibrium time of 30 min by programmed temperature. RESULTS:The linear range of acetaldehyde was 0.002~0.02 mg·L-1(r=0.999 1) with average recovery of 98.37%(RSD=2.82%,n=6) . The detection limit was 0.1 ng. CONCLUSION:The method is accurate,relibale and can be used for determination of the limit of acetaldehyde in oral liquid PET bottle.

About this research paper

What this paper is about

OBJECTIVE:To establish the method for determination of residual acetaldehyde in oral liquid PET bottle. METHODS:Headspace gas chromatography was adopted. The determination was performed on DB-FFAP capillary column. FID detector was used with injector temperature of 200 ℃ and detector temperature of 200 ℃ using nitrogen as carrier gas. The equilibrium temperature of headspace sampling was set at 70 ℃ with equilibrium time of 30 min by programmed temperature. RESULTS:The linear range of acetaldehyde was 0.002~0.02 mg·L-1(r=0.999 1) with average recovery of 98.37%(RSD=2.82%,n=6) . The detection limit was 0.1 ng. CONCLUSION:The method is accurate,relibale and can be used for determination of the limit of acetaldehyde in oral liquid PET bottle.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE:To establish the method for determination of residual acetaldehyde in oral liquid PET bottle. METHODS:Headspace gas chromatography was adopted. The determination was performed on DB-FFAP capillary column. FID detector was used with injector temperature of 200 ℃ and detector temperature of 200 ℃ using nitrogen as carrier gas. The equilibrium temperature of headspace sampling was set at 70 ℃ with equilibrium time of 30 min by programmed temperature. RESULTS:The linear range of acetaldehyde was 0.002~0.02 mg·L-1(r=0.999 1) with average recovery of 98.37%(RSD=2.82%,n=6) . The detection limit was 0.1 ng. CONCLUSION:The method is accurate,relibale and can be used for determination of the limit of acetaldehyde in oral liquid PET bottle.

Key concepts: Acetaldehyde, Chromatography, Bottle, Chemistry, Detection limit, Gas chromatography, Residual, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Residual Acetaldehyde in Oral Liquid PET Bottle by Headspace Gas Chromatography — Research Paper | ScholarLens