Determination of Organic Solvents Remained in Terpene Resin with Gas Chromatography and Its Application
Bi LiangWu
Abstract
Bi LiangWu
Abstract
The determination technique and method of organic solvents remained in terpene resin was studied by gas chromatography.According to drawing standard curve,testing the precision and repeatability,calculating the lowest detection limit and determining recovery ratio,its feasibility was confirmed.Its practical application effect was further investigated.The results indicated that,the lowest detection limits determined by capillary gas chromatography for toluene,1,2-dichlorethane and benzene were 0.2 mg/L,1.7 mg/L,and 0.3 mg/L,respectively.For toluene determination,the standard deviation of determining precision is 0.04;recovery ratio and its standard deviation are 104.1 % and 1.99,respectively.While applying the method to determine samples of terpene resin prepared in laboratory,it showed that there was only toluene as organic solvent in the resins and its residual contents was less than 25 mg/kg.No benzene and 1,2-dichloroethane were indicated in the resins.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The determination technique and method of organic solvents remained in terpene resin was studied by gas chromatography.According to drawing standard curve,testing the precision and repeatability,calculating the lowest detection limit and determining recovery ratio,its feasibility was confirmed.Its practical application effect was further investigated.The results indicated that,the lowest detection limits determined by capillary gas chromatography for toluene,1,2-dichlorethane and benzene were 0.2 mg/L,1.7 mg/L,and 0.3 mg/L,respectively.For toluene determination,the standard deviation of determining precision is 0.04;recovery ratio and its standard deviation are 104.1 % and 1.99,respectively.While applying the method to determine samples of terpene resin prepared in laboratory,it showed that there was only toluene as organic solvent in the resins and its residual contents was less than 25 mg/kg.No benzene and 1,2-dichloroethane were indicated in the resins.
Key concepts: Toluene, Repeatability, Benzene, Gas chromatography, Chromatography, Detection limit, Chemistry, Terpene