2010Zhongguo shuxue zazhiRequires access

Hemostatic efficacy of fibrin dressing

Cao Xiaohan

Open publisher page 1 citations

Abstract

Objective To evaluate the hemostatic efficacy of fibrin dressing in animal models of femoral artery transection and liver injury. Methods Fibrin dressing and collagen sponge were used in Wistar rat femoral artery incision and rabbit partial liver resections. The time to achieve complete hemostasis was recorded for each animal, as well as the blood loss. Results In femoral artery injury model, hemostasis occurred (90.60±33.12) s later in the fibrin dressing group, with the blood loss of (0.51±0.26) ml. In the collagen sponge group, hemostasis occurred (164.20±53.70) s later, with the blood loss of (1.04±0.50)ml. Statistical analysis showed significant difference between these two groups (P0.05). In liver injury model, hemostasis occurred (48.67±8.14) s later in the fibrin dressing group, with blood loss of (0.82±0.09) ml. In the collagen sponge group, hemostasis occurred (107.67±6.66) s later, with the blood loss of (1.07±0.13) ml. Statistical analysis showed significant difference between these two groups (P0.05). Conclusion The hemostatic effect of fibrin dressing is better than collagen sponge, and fibrin dressing is a good topical hemostatic .

About this research paper

What this paper is about

Objective To evaluate the hemostatic efficacy of fibrin dressing in animal models of femoral artery transection and liver injury. Methods Fibrin dressing and collagen sponge were used in Wistar rat femoral artery incision and rabbit partial liver resections. The time to achieve complete hemostasis was recorded for each animal, as well as the blood loss. Results In femoral artery injury model, hemostasis occurred (90.60±33.12) s later in the fibrin dressing group, with the blood loss of (0.51±0.26) ml. In the collagen sponge group, hemostasis occurred (164.20±53.70) s later, with the blood loss of (1.04±0.50)ml. Statistical analysis showed significant difference between these two groups (P0.05). In liver injury model, hemostasis occurred (48.67±8.14) s later in the fibrin dressing group, with blood loss of (0.82±0.09) ml. In the collagen sponge group, hemostasis occurred (107.67±6.66) s later, with the blood loss of (1.07±0.13) ml. Statistical analysis showed significant difference between these two groups (P0.05). Conclusion The hemostatic effect of fibrin dressing is better than collagen sponge, and fibrin dressing is a good topical hemostatic .

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the hemostatic efficacy of fibrin dressing in animal models of femoral artery transection and liver injury. Methods Fibrin dressing and collagen sponge were used in Wistar rat femoral artery incision and rabbit partial liver resections. The time to achieve complete hemostasis was recorded for each animal, as well as the blood loss. Results In femoral artery injury model, hemostasis occurred (90.60±33.12) s later in the fibrin dressing group, with the blood loss of (0.51±0.26) ml. In the collagen sponge group, hemostasis occurred (164.20±53.70) s later, with the blood loss of (1.04±0.50)ml. Statistical analysis showed significant difference between these two groups (P0.05). In liver injury model, hemostasis occurred (48.67±8.14) s later in the fibrin dressing group, with blood loss of (0.82±0.09) ml. In the collagen sponge group, hemostasis occurred (107.67±6.66) s later, with the blood loss of (1.07±0.13) ml. Statistical analysis showed significant difference between these two groups (P0.05). Conclusion The hemostatic effect of fibrin dressing is better than collagen sponge, and fibrin dressing is a good topical hemostatic .

Key concepts: Hemostasis, Fibrin, Medicine, Femoral artery, Hemostatic Agent, Blood loss, Surgery, Artery

Related papers

Back to paper searchBrowse research topicsOriginal source
Hemostatic efficacy of fibrin dressing — Research Paper | ScholarLens