2007ZhongchengyaoRequires access

Quality standard of Agui Yangxue Tablets

Genquan Yan

Open publisher page 0 citations

Abstract

AIM: To establish the quality standard of Agui Yangxue Tablets (Radix Angelicae sinensis, Radix Codonopsis, Rhizoma Atractylodis macrocephalae, etc.) METHODS: Radix Astragali, Radix et Rhizoma Glycyrrhizae and Radix Rehmanniae praeparata were identified by TLC. The content of ferulic acid and paeoniflorin was determined by HPLC. The HPLC condition of ferulic acid was as follows: column was Diamonsil~ TM C_ 18 (4.6 mm×200 mm,5 μm), the mobile phase consisted of acetonitrile -0.085% phosphoric acid (22 ∶ 78), the UV detection wavelength was at 322 nm, the flow rate was 1.0 mL/min with column temperature at 35 °C . The HPLC condition of paeoniflorin was as follows: column was Diamonsil~ TM C_ 18 (4.6 mm×200 mm,5 μm), the mobile phase consisted of acetonitrile -0.1% phosphoric acid (15 ∶ 85), the UV detection wavelength was at 229 nm, the flow rate was 1.0 mL/min with column temperature at 25 °C . RESULTS: The developed TLC spots were quite clear. The calibration curve of ferulic acid was linear with 0.012 9-0.154 8 μg(r=0.999 7). The average recovery was 99.32% with RSD of 1.74% (n=9). The calibration curve of paeoniflorin was linear with 0.106 8-1.602 0 μg(r= 0.999 9). The average recovery was 98.68% with RSD of 0.98 (n=9). CONCLUSION: The established TLC and HPLC methods are exclusive, reproducible and suitable for the quality control of Agui Yangxue Tables.

About this research paper

What this paper is about

AIM: To establish the quality standard of Agui Yangxue Tablets (Radix Angelicae sinensis, Radix Codonopsis, Rhizoma Atractylodis macrocephalae, etc.) METHODS: Radix Astragali, Radix et Rhizoma Glycyrrhizae and Radix Rehmanniae praeparata were identified by TLC. The content of ferulic acid and paeoniflorin was determined by HPLC. The HPLC condition of ferulic acid was as follows: column was Diamonsil~ TM C_ 18 (4.6 mm×200 mm,5 μm), the mobile phase consisted of acetonitrile -0.085% phosphoric acid (22 ∶ 78), the UV detection wavelength was at 322 nm, the flow rate was 1.0 mL/min with column temperature at 35 °C . The HPLC condition of paeoniflorin was as follows: column was Diamonsil~ TM C_ 18 (4.6 mm×200 mm,5 μm), the mobile phase consisted of acetonitrile -0.1% phosphoric acid (15 ∶ 85), the UV detection wavelength was at 229 nm, the flow rate was 1.0 mL/min with column temperature at 25 °C . RESULTS: The developed TLC spots were quite clear. The calibration curve of ferulic acid was linear with 0.012 9-0.154 8 μg(r=0.999 7). The average recovery was 99.32% with RSD of 1.74% (n=9). The calibration curve of paeoniflorin was linear with 0.106 8-1.602 0 μg(r= 0.999 9). The average recovery was 98.68% with RSD of 0.98 (n=9). CONCLUSION: The established TLC and HPLC methods are exclusive, reproducible and suitable for the quality control of Agui Yangxue Tables.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AIM: To establish the quality standard of Agui Yangxue Tablets (Radix Angelicae sinensis, Radix Codonopsis, Rhizoma Atractylodis macrocephalae, etc.) METHODS: Radix Astragali, Radix et Rhizoma Glycyrrhizae and Radix Rehmanniae praeparata were identified by TLC. The content of ferulic acid and paeoniflorin was determined by HPLC. The HPLC condition of ferulic acid was as follows: column was Diamonsil~ TM C_ 18 (4.6 mm×200 mm,5 μm), the mobile phase consisted of acetonitrile -0.085% phosphoric acid (22 ∶ 78), the UV detection wavelength was at 322 nm, the flow rate was 1.0 mL/min with column temperature at 35 °C . The HPLC condition of paeoniflorin was as follows: column was Diamonsil~ TM C_ 18 (4.6 mm×200 mm,5 μm), the mobile phase consisted of acetonitrile -0.1% phosphoric acid (15 ∶ 85), the UV detection wavelength was at 229 nm, the flow rate was 1.0 mL/min with column temperature at 25 °C . RESULTS: The developed TLC spots were quite clear. The calibration curve of ferulic acid was linear with 0.012 9-0.154 8 μg(r=0.999 7). The average recovery was 99.32% with RSD of 1.74% (n=9). The calibration curve of paeoniflorin was linear with 0.106 8-1.602 0 μg(r= 0.999 9). The average recovery was 98.68% with RSD of 0.98 (n=9). CONCLUSION: The established TLC and HPLC methods are exclusive, reproducible and suitable for the quality control of Agui Yangxue Tables.

Key concepts: Paeoniflorin, Chromatography, Phosphoric acid, Radix (gastropod), Ferulic acid, Calibration curve, Chemistry, High-performance liquid chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Quality standard of Agui Yangxue Tablets — Research Paper | ScholarLens