2010Journal of Hebei Agricultural SciencesRequires access

Study on the Determination of Arsenic and Mercury in Tobacco by Atomic Fluorescence Spectrometry

Chen Yongkuan

Open publisher page 0 citations

Abstract

The determination of arsenic and mercury in tobacco by atomic fluorescence spectrometry was studied.The tobacco samples were digested with HNO3-HClO4,then the arsenic and mercury were determined by atomic fluorescence spectrometry.The detection limits of arsenic and mercury were 0.05 ng/mL and 0.008 ng/mL,respectively.The relative standard deviation of arsenic and mercury were 2.6% and 2.7%,respectively.The recovery of standard addition of arsenic and mercury were 96%-103% and 94%-102%,respectively.

About this research paper

What this paper is about

The determination of arsenic and mercury in tobacco by atomic fluorescence spectrometry was studied.The tobacco samples were digested with HNO3-HClO4,then the arsenic and mercury were determined by atomic fluorescence spectrometry.The detection limits of arsenic and mercury were 0.05 ng/mL and 0.008 ng/mL,respectively.The relative standard deviation of arsenic and mercury were 2.6% and 2.7%,respectively.The recovery of standard addition of arsenic and mercury were 96%-103% and 94%-102%,respectively.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The determination of arsenic and mercury in tobacco by atomic fluorescence spectrometry was studied.The tobacco samples were digested with HNO3-HClO4,then the arsenic and mercury were determined by atomic fluorescence spectrometry.The detection limits of arsenic and mercury were 0.05 ng/mL and 0.008 ng/mL,respectively.The relative standard deviation of arsenic and mercury were 2.6% and 2.7%,respectively.The recovery of standard addition of arsenic and mercury were 96%-103% and 94%-102%,respectively.

Key concepts: Arsenic, Mercury (programming language), Relative standard deviation, Chemistry, Detection limit, Fluorescence spectrometry, Environmental chemistry, Mass spectrometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the Determination of Arsenic and Mercury in Tobacco by Atomic Fluorescence Spectrometry — Research Paper | ScholarLens