2004PubMedRequires access

[Phonation assessment of voice restoration after laryngectomy].

Shufen Xiao, Xiaoming Li, Yao-dong Shang, Qi Li, Yinfang He

Open publisher page 3 citations

Abstract

OBJECTIVE: To take an objective phonation assessment for the patients who have taken the tracheo-esophageal (TE) shunt procedure after total laryngectomy. METHOD: Twenty-four patients after TE shunt procedure were selected as TE group. Esophageal speakers after total laryngectomy and normal subjects were considered as controls. All the subjects of three groups took part in the voice acoustic assessment and MPT measurement. Twenty TE speakers took part in intra-tracheal pressure measurement. TE speakers and esophageal speakers participated in the electronic laryngoscope examination. RESULT: There were no significant differences between TE group and esophageal group in every acoustic parameters, but there were very remarkable differences between TE group and normal subjects in jitter, shimmer, harmonics to noise ratio and normalized noise energy. The pressure of TE speakers for comfortable /a/ is (2.86 +/- 0.69) kPa. The pharyno-esophageal segment vibrated regularly in most alaryngeal speakers and shapes of neo-glottis of most alaryngeal speakers were circular. CONCLUSION: Acoustic parameters of TE speakers were similar to those of esophageal speakers, but the tone of TE speakers was more similar to the normal controls. Speaking of the patients after the TE shunt procedure is laborsaving.

About this research paper

What this paper is about

OBJECTIVE: To take an objective phonation assessment for the patients who have taken the tracheo-esophageal (TE) shunt procedure after total laryngectomy. METHOD: Twenty-four patients after TE shunt procedure were selected as TE group. Esophageal speakers after total laryngectomy and normal subjects were considered as controls. All the subjects of three groups took part in the voice acoustic assessment and MPT measurement. Twenty TE speakers took part in intra-tracheal pressure measurement. TE speakers and esophageal speakers participated in the electronic laryngoscope examination. RESULT: There were no significant differences between TE group and esophageal group in every acoustic parameters, but there were very remarkable differences between TE group and normal subjects in jitter, shimmer, harmonics to noise ratio and normalized noise energy. The pressure of TE speakers for comfortable /a/ is (2.86 +/- 0.69) kPa. The pharyno-esophageal segment vibrated regularly in most alaryngeal speakers and shapes of neo-glottis of most alaryngeal speakers were circular. CONCLUSION: Acoustic parameters of TE speakers were similar to those of esophageal speakers, but the tone of TE speakers was more similar to the normal controls. Speaking of the patients after the TE shunt procedure is laborsaving.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To take an objective phonation assessment for the patients who have taken the tracheo-esophageal (TE) shunt procedure after total laryngectomy. METHOD: Twenty-four patients after TE shunt procedure were selected as TE group. Esophageal speakers after total laryngectomy and normal subjects were considered as controls. All the subjects of three groups took part in the voice acoustic assessment and MPT measurement. Twenty TE speakers took part in intra-tracheal pressure measurement. TE speakers and esophageal speakers participated in the electronic laryngoscope examination. RESULT: There were no significant differences between TE group and esophageal group in every acoustic parameters, but there were very remarkable differences between TE group and normal subjects in jitter, shimmer, harmonics to noise ratio and normalized noise energy. The pressure of TE speakers for comfortable /a/ is (2.86 +/- 0.69) kPa. The pharyno-esophageal segment vibrated regularly in most alaryngeal speakers and shapes of neo-glottis of most alaryngeal speakers were circular. CONCLUSION: Acoustic parameters of TE speakers were similar to those of esophageal speakers, but the tone of TE speakers was more similar to the normal controls. Speaking of the patients after the TE shunt procedure is laborsaving.

Key concepts: Laryngectomy, Esophageal speech, Phonation, Audiology, Glottis, Medicine, Electroglottograph, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
[Phonation assessment of voice restoration after laryngectomy]. — Research Paper | ScholarLens