2008Unpublished venueRequires access

Study on fingerprints of Yexiazhu capsules by HPLC

Rao Li-qun

Open publisher page 0 citations

Abstract

Objective To develop a fingerprint with HPLC method for determination of the Yexiazhu capsules.Method The RP-HPLC method was used with that Hypersil ODSⅡ column was 250 mm ×4.6 mm,5 um,mobile phase was acetonitrile-0.1% phosphoric acid(gradient elution);analytic time was 65 min,the flow rate was 0.8 ml/min,and detective wavelength was at 280 nm.Results A standard HPLC fingerprint procedure of Yexiazhu capsules was developed with 17 common peaks and a similarity threshold of 0.91 established.Conclusion The method is reliable and simple which can be used for quality control of the capsule.

About this research paper

What this paper is about

Objective To develop a fingerprint with HPLC method for determination of the Yexiazhu capsules.Method The RP-HPLC method was used with that Hypersil ODSⅡ column was 250 mm ×4.6 mm,5 um,mobile phase was acetonitrile-0.1% phosphoric acid(gradient elution);analytic time was 65 min,the flow rate was 0.8 ml/min,and detective wavelength was at 280 nm.Results A standard HPLC fingerprint procedure of Yexiazhu capsules was developed with 17 common peaks and a similarity threshold of 0.91 established.Conclusion The method is reliable and simple which can be used for quality control of the capsule.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To develop a fingerprint with HPLC method for determination of the Yexiazhu capsules.Method The RP-HPLC method was used with that Hypersil ODSⅡ column was 250 mm ×4.6 mm,5 um,mobile phase was acetonitrile-0.1% phosphoric acid(gradient elution);analytic time was 65 min,the flow rate was 0.8 ml/min,and detective wavelength was at 280 nm.Results A standard HPLC fingerprint procedure of Yexiazhu capsules was developed with 17 common peaks and a similarity threshold of 0.91 established.Conclusion The method is reliable and simple which can be used for quality control of the capsule.

Key concepts: Chromatography, Phosphoric acid, High-performance liquid chromatography, Gradient elution, Fingerprint (computing), Capsule, Chemistry, Acetonitrile

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on fingerprints of Yexiazhu capsules by HPLC — Research Paper | ScholarLens