2010Chinese Journal of Health Laboratory TechnologyRequires access

Rapid detection of microcystin-LR in drinking water by ultra-fast liquid chromatography tandem mass spectrometry

Guilan Xu

Open publisher page 0 citations

Abstract

Objective:To establish a rapid,accurate method detection microcystin-LR in drinking water.Methods:Using the m/z 498.4/135.0 for ions to establish the MRM method.After the water boil 30 minutes,using C18 solid phase extraction column to extract and purify then using 5 ml 0.1% formic acid methanol solution to elute,dried by nitrogen then constant volume to 1ml,pass the 0.22μm membrane then determination on the machine.Results:After optimization,pre-processing time only 4 hours.The minimum detection limit is 0.004 μg/L,the linear equation: Y=2.13e+003X+9.09,the correlation coefficient is 0.9996,the recovery rate is in the range of 75.8%~104.5,the average recovery rate is 86.3%,RSD 3.5%(n=6).Conclusion:This method can rapidly and accurately detect microcystin-LR in drinking water.

About this research paper

What this paper is about

Objective:To establish a rapid,accurate method detection microcystin-LR in drinking water.Methods:Using the m/z 498.4/135.0 for ions to establish the MRM method.After the water boil 30 minutes,using C18 solid phase extraction column to extract and purify then using 5 ml 0.1% formic acid methanol solution to elute,dried by nitrogen then constant volume to 1ml,pass the 0.22μm membrane then determination on the machine.Results:After optimization,pre-processing time only 4 hours.The minimum detection limit is 0.004 μg/L,the linear equation: Y=2.13e+003X+9.09,the correlation coefficient is 0.9996,the recovery rate is in the range of 75.8%~104.5,the average recovery rate is 86.3%,RSD 3.5%(n=6).Conclusion:This method can rapidly and accurately detect microcystin-LR in drinking water.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish a rapid,accurate method detection microcystin-LR in drinking water.Methods:Using the m/z 498.4/135.0 for ions to establish the MRM method.After the water boil 30 minutes,using C18 solid phase extraction column to extract and purify then using 5 ml 0.1% formic acid methanol solution to elute,dried by nitrogen then constant volume to 1ml,pass the 0.22μm membrane then determination on the machine.Results:After optimization,pre-processing time only 4 hours.The minimum detection limit is 0.004 μg/L,the linear equation: Y=2.13e+003X+9.09,the correlation coefficient is 0.9996,the recovery rate is in the range of 75.8%~104.5,the average recovery rate is 86.3%,RSD 3.5%(n=6).Conclusion:This method can rapidly and accurately detect microcystin-LR in drinking water.

Key concepts: Chemistry, Chromatography, Formic acid, Microcystin, Detection limit, Tap water, Elution, Extraction (chemistry)