2001PubMedRequires access

[Simultaneous determination of various food additives by high performance liquid chromatography].

Q C Chen, Wenhui Yu, J Wang

Open publisher page 1 citations

Abstract

A novel method is proposed for the simultaneous separation and determination of eight food additives, acesulfame potassium (AK), aspartame (ASP), benzoic acid (BA), caffeine (CA), saccharin sodium (SA), sorbic acid (SOR), theobromine (TB) and theophylline (TP) by reversed-phase high performance liquid chromatography. The separation was achieved within 23 min by using an Alltech Econosphere C18 column with 10 mmol/L NaH2PO4(pH 4.00)-acetonitrile (90:10, V/V) as mobile phase. The qualification and quantitation were accomplished by using a photodiode array detector. The detection limits (S/N = 3) for all analytes were below mg/L level. Under the experimental conditions, other common food additives and organic acids such as cyclamate, citric acid, malic acid, tartaric acid and ascorbic acid, did not interfere with the determination. The method has been successfully applied to the analysis of various foods as well as pharmaceutical preparation, and the average recoveries for real samples ranged from 78.5% to 107.2%.

About this research paper

What this paper is about

A novel method is proposed for the simultaneous separation and determination of eight food additives, acesulfame potassium (AK), aspartame (ASP), benzoic acid (BA), caffeine (CA), saccharin sodium (SA), sorbic acid (SOR), theobromine (TB) and theophylline (TP) by reversed-phase high performance liquid chromatography. The separation was achieved within 23 min by using an Alltech Econosphere C18 column with 10 mmol/L NaH2PO4(pH 4.00)-acetonitrile (90:10, V/V) as mobile phase. The qualification and quantitation were accomplished by using a photodiode array detector. The detection limits (S/N = 3) for all analytes were below mg/L level. Under the experimental conditions, other common food additives and organic acids such as cyclamate, citric acid, malic acid, tartaric acid and ascorbic acid, did not interfere with the determination. The method has been successfully applied to the analysis of various foods as well as pharmaceutical preparation, and the average recoveries for real samples ranged from 78.5% to 107.2%.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A novel method is proposed for the simultaneous separation and determination of eight food additives, acesulfame potassium (AK), aspartame (ASP), benzoic acid (BA), caffeine (CA), saccharin sodium (SA), sorbic acid (SOR), theobromine (TB) and theophylline (TP) by reversed-phase high performance liquid chromatography. The separation was achieved within 23 min by using an Alltech Econosphere C18 column with 10 mmol/L NaH2PO4(pH 4.00)-acetonitrile (90:10, V/V) as mobile phase. The qualification and quantitation were accomplished by using a photodiode array detector. The detection limits (S/N = 3) for all analytes were below mg/L level. Under the experimental conditions, other common food additives and organic acids such as cyclamate, citric acid, malic acid, tartaric acid and ascorbic acid, did not interfere with the determination. The method has been successfully applied to the analysis of various foods as well as pharmaceutical preparation, and the average recoveries for real samples ranged from 78.5% to 107.2%.

Key concepts: Chemistry, Chromatography, Aspartame, Sorbic acid, Citric acid, Theobromine, High-performance liquid chromatography, Tartaric acid

Related papers

Back to paper searchBrowse research topicsOriginal source
[Simultaneous determination of various food additives by high performance liquid chromatography]. — Research Paper | ScholarLens