2014•Applied and Computational MechanicsOpen access

Effect of Wind on Thermal Performance of Heller Dry Cooling Tower

Ali M. Ardekani, Foad Farhani, Mohsen Mazidi

Open full text 1 citations

Abstract

In a steam power plant, the temperature of the cooling water leaving the condenser for recyclingshould decrease. This is achieved in a cooling tower. The Heller cooling tower does not require waterfor operation, thus, it is a suitable system for use in thermal power plants throughout Iran. Wind is anenvironmental factor that unfavorably affects the performance of a cooling tower. Previous studieshave not considered real prevailing conditions appropriately; their conclusions are incomplete and, attimes, contradictory. The present field study of the cooling tower at Montazer-Ghaem Power Plant inthe city of Karaj in Iran investigated the effect of wind on the thermal performance of the coolingtower. Wind velocity was measured using blade-and-cup type digital anemometers. The direction ofthe wind around the cooling tower was determined using tufts. Ultrasonic flow meters and resistancethermometers were used to measure the flow rates and temperatures of the water at the inlet and outlet,respectively. Results show that, despite air suction, no separation occurred at the periphery of thecooling tower. The front cooling sectors that face the wind and the back sectors that do not directlyface the wind were more thermally efficient. They transferred about 60% more heat than did thecooling sectors parallel to the wind direction at the periphery of the cooling tower. The results alsoshowed that thermal performance in the front and back cooling sectors increased as the wind velocityincreased and that in the peripheral sectors decreased.

About this research paper

What this paper is about

In a steam power plant, the temperature of the cooling water leaving the condenser for recyclingshould decrease. This is achieved in a cooling tower. The Heller cooling tower does not require waterfor operation, thus, it is a suitable system for use in thermal power plants throughout Iran. Wind is anenvironmental factor that unfavorably affects the performance of a cooling tower. Previous studieshave not considered real prevailing conditions appropriately; their conclusions are incomplete and, attimes, contradictory. The present field study of the cooling tower at Montazer-Ghaem Power Plant inthe city of Karaj in Iran investigated the effect of wind on the thermal performance of the coolingtower. Wind velocity was measured using blade-and-cup type digital anemometers. The direction ofthe wind around the cooling tower was determined using tufts. Ultrasonic flow meters and resistancethermometers were used to measure the flow rates and temperatures of the water at the inlet and outlet,respectively. Results show that, despite air suction, no separation occurred at the periphery of thecooling tower. The front cooling sectors that face the wind and the back sectors that do not directlyface the wind were more thermally efficient. They transferred about 60% more heat than did thecooling sectors parallel to the wind direction at the periphery of the cooling tower. The results alsoshowed that thermal performance in the front and back cooling sectors increased as the wind velocityincreased and that in the peripheral sectors decreased.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In a steam power plant, the temperature of the cooling water leaving the condenser for recyclingshould decrease. This is achieved in a cooling tower. The Heller cooling tower does not require waterfor operation, thus, it is a suitable system for use in thermal power plants throughout Iran. Wind is anenvironmental factor that unfavorably affects the performance of a cooling tower. Previous studieshave not considered real prevailing conditions appropriately; their conclusions are incomplete and, attimes, contradictory. The present field study of the cooling tower at Montazer-Ghaem Power Plant inthe city of Karaj in Iran investigated the effect of wind on the thermal performance of the coolingtower. Wind velocity was measured using blade-and-cup type digital anemometers. The direction ofthe wind around the cooling tower was determined using tufts. Ultrasonic flow meters and resistancethermometers were used to measure the flow rates and temperatures of the water at the inlet and outlet,respectively. Results show that, despite air suction, no separation occurred at the periphery of thecooling tower. The front cooling sectors that face the wind and the back sectors that do not directlyface the wind were more thermally efficient. They transferred about 60% more heat than did thecooling sectors parallel to the wind direction at the periphery of the cooling tower. The results alsoshowed that thermal performance in the front and back cooling sectors increased as the wind velocityincreased and that in the peripheral sectors decreased.

Key concepts: Cooling tower, Condenser (optics), Environmental science, Tower, Wind speed, Marine engineering, Anemometer, Heat exchanger

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of Wind on Thermal Performance of Heller Dry Cooling Tower — Research Paper | ScholarLens