Applied anatomy of transposition of partial tendon of flexor carpi ulnaris to repair dislocation of distal radio-ulnar joint
Lin Yong-sui
Abstract
Lin Yong-sui
Abstract
Objective:To provide anatom icalbasisforthe operation ofrepairing dislocation ofthe distalradio-ulnar joint adopting the tendon of flexor carpi ulnaris. M ethods:To classify the tendon offlexor carpiulnaris into three parts: upper, middle and inferior parts. Morphologic measures and the mechanic test of tendonof flexor carpi ulnaris were performed on 30 sides of adult cadavers. Results:The w idth oftendon offlexorcarpi ulnaris was about (7.6±0.9)mm, ( 6.4±0.7)mm and ( 5.5±0.6)mm at upper, middle and inferior partrespectively, while the thickness of tendon of flexor carpi ulnaris was about (1.7±0.3)mm, (2.0±0.3)mm and(2.3±0.2)mm seperately. The length of tendon was (16.7±2.7)cm. The results of mechanic test showed that theload on the integrity tendon of flexor carpi ulnaris was (266.7±45.2)N, and (107.2±19.9 )N on the half tendon.They had no significant difference. Conclusions:There are enough length and intensity to repairdislocation ofthe distal radio-ulnar joint by the transposition of patial tendon of flexor carpi ulnaris. Satisfactory results havebeen obtained in clinic practice.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To provide anatom icalbasisforthe operation ofrepairing dislocation ofthe distalradio-ulnar joint adopting the tendon of flexor carpi ulnaris. M ethods:To classify the tendon offlexor carpiulnaris into three parts: upper, middle and inferior parts. Morphologic measures and the mechanic test of tendonof flexor carpi ulnaris were performed on 30 sides of adult cadavers. Results:The w idth oftendon offlexorcarpi ulnaris was about (7.6±0.9)mm, ( 6.4±0.7)mm and ( 5.5±0.6)mm at upper, middle and inferior partrespectively, while the thickness of tendon of flexor carpi ulnaris was about (1.7±0.3)mm, (2.0±0.3)mm and(2.3±0.2)mm seperately. The length of tendon was (16.7±2.7)cm. The results of mechanic test showed that theload on the integrity tendon of flexor carpi ulnaris was (266.7±45.2)N, and (107.2±19.9 )N on the half tendon.They had no significant difference. Conclusions:There are enough length and intensity to repairdislocation ofthe distal radio-ulnar joint by the transposition of patial tendon of flexor carpi ulnaris. Satisfactory results havebeen obtained in clinic practice.
Key concepts: Flexor Carpi Ulnaris, Extensor Carpi Ulnaris, Anatomy, Medicine, Tendon, Cadaver, Ulnar nerve, Elbow