Application Value of 16-slice Spiral CT for Diagnosis of Aortic Aneurysms
Huang Guixiong
Abstract
Huang Guixiong
Abstract
Objective To evaluate the efficacy of 16-slice Spiral CT angiography(CTA) with post-processing techniques in the diagnosis of aortic aneurysms.Methods A total of 30 patients with aortic aneurysms confirmed by surgery or DSA were recruited.Patients' images of 16-slice Spiral CT scanning CTA were retrospectively analyzed.All original images data were dealt with adw4.2 workstation.Reconstruction was performed in several ways,that is,by shaded volume reconstruction(SVR),multi-planar reconstructions(MPR),maximum intensity reformation(MIP),and curved planar reformation(CPR),and CT virtual endoscopy(CTVE).Results There were 2 cases of ascending aortic aneurysm,7 cases of descending aortic aneurysm,9 cases of abdominal aortic aneurysm and 12 cases of artery pseudo aneurysm including 4 ones of ascending artery pseudo aneurysm,4 ones of descending artery pseudo aneurysm and 4 ones of abdominal artery pseudo aneurysm.Conclusion 16-slice Spiral CT can show anatomy change of aortic aneurysms exactly,rapidly and non-invasively,and thus is important for treatment scheme establishment,post-operation observation and follow up.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To evaluate the efficacy of 16-slice Spiral CT angiography(CTA) with post-processing techniques in the diagnosis of aortic aneurysms.Methods A total of 30 patients with aortic aneurysms confirmed by surgery or DSA were recruited.Patients' images of 16-slice Spiral CT scanning CTA were retrospectively analyzed.All original images data were dealt with adw4.2 workstation.Reconstruction was performed in several ways,that is,by shaded volume reconstruction(SVR),multi-planar reconstructions(MPR),maximum intensity reformation(MIP),and curved planar reformation(CPR),and CT virtual endoscopy(CTVE).Results There were 2 cases of ascending aortic aneurysm,7 cases of descending aortic aneurysm,9 cases of abdominal aortic aneurysm and 12 cases of artery pseudo aneurysm including 4 ones of ascending artery pseudo aneurysm,4 ones of descending artery pseudo aneurysm and 4 ones of abdominal artery pseudo aneurysm.Conclusion 16-slice Spiral CT can show anatomy change of aortic aneurysms exactly,rapidly and non-invasively,and thus is important for treatment scheme establishment,post-operation observation and follow up.
Key concepts: Medicine, Aneurysm, Radiology, Angiography, Abdominal aortic aneurysm, Aortic aneurysm, Artery, Surgery