Analytic performance evaluation of five kinds of point-of-care testing blood glucose meters

Yanlin Luo

Open publisher page 0 citations

Abstract

Objective To evaluate the analytic performance of five kinds of blood glucose meters.Methods Three fresh whole blood samples of different levels of glucose and two levels of glucose quality controls were determined by five different kinds of point-of-care testing(POCT) blood glucose meters and the precision was evaluated.Twenty fresh whole blood samples were detected by five detection systems in five days.The results were analysed the correlation with target system(Roche Modular PPI automatic biochemical analyser and relevant reagent,calibrator and quality controls) in order to evaluate their accuracy.The technology of five detection systems were evaluted.Results The precision and accuracy of all detection systems were less than half of permit range about glucose POCT established by National Committee for Clinical Laboratory Standards(NCCLS),especially the detection system 3.The correlation coefficients between the evaluated detection system and the target detection system were all more than 0.975.The relative bias of the detection system 1 was the least.Conclusions The precision and accuracy of five detection systems were accorded with clinical requirements.

About this research paper

What this paper is about

Objective To evaluate the analytic performance of five kinds of blood glucose meters.Methods Three fresh whole blood samples of different levels of glucose and two levels of glucose quality controls were determined by five different kinds of point-of-care testing(POCT) blood glucose meters and the precision was evaluated.Twenty fresh whole blood samples were detected by five detection systems in five days.The results were analysed the correlation with target system(Roche Modular PPI automatic biochemical analyser and relevant reagent,calibrator and quality controls) in order to evaluate their accuracy.The technology of five detection systems were evaluted.Results The precision and accuracy of all detection systems were less than half of permit range about glucose POCT established by National Committee for Clinical Laboratory Standards(NCCLS),especially the detection system 3.The correlation coefficients between the evaluated detection system and the target detection system were all more than 0.975.The relative bias of the detection system 1 was the least.Conclusions The precision and accuracy of five detection systems were accorded with clinical requirements.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the analytic performance of five kinds of blood glucose meters.Methods Three fresh whole blood samples of different levels of glucose and two levels of glucose quality controls were determined by five different kinds of point-of-care testing(POCT) blood glucose meters and the precision was evaluated.Twenty fresh whole blood samples were detected by five detection systems in five days.The results were analysed the correlation with target system(Roche Modular PPI automatic biochemical analyser and relevant reagent,calibrator and quality controls) in order to evaluate their accuracy.The technology of five detection systems were evaluted.Results The precision and accuracy of all detection systems were less than half of permit range about glucose POCT established by National Committee for Clinical Laboratory Standards(NCCLS),especially the detection system 3.The correlation coefficients between the evaluated detection system and the target detection system were all more than 0.975.The relative bias of the detection system 1 was the least.Conclusions The precision and accuracy of five detection systems were accorded with clinical requirements.

Key concepts: Analyser, External quality assessment, Point-of-care testing, Point of care, Accuracy and precision, Medicine, Computer science, Statistics

Related papers

Back to paper searchBrowse research topicsOriginal source
Analytic performance evaluation of five kinds of point-of-care testing blood glucose meters — Research Paper | ScholarLens