2012•Unpublished venueRequires access

GC/MS Analysis of Chemical Agent Simulants in Water and Soil

Xinrui Wang

Open publisher page 0 citations

Abstract

In order to rapid deal with the unexpected incidents of chemical agents,a method based on gas chromatography spectrometry(GC/MS) was developed for the determination of nerve warfare agent and vesicant agent simulants in water and soil.The water was extracted by dichloromethane and acetonitrile,the soil was extracted by dichloromethane,then the extract was separated on a HP-5MS column(30 m×0.25 mm×0.25 μm) and the identification and quantification of the analytes were carried out in the choice ion(SIM) mode.The six point calibration curves showed a good linearity for all the congeners(0.998 4~0.999 9).Limits of detection(LODs) of the water ranged from 0.3 to 2.1 μg/L and the soil ranged from 1.0 to 2.7 μg/kg.The relative standard deviations(RSDs) of water and soil were below 11.5%、11.8% respectively.The spiked recoveries of water and soil were in the range of 70.5%~101.9%、70.8%~112.9% respectively.The developed analytical method is rapid and accurate,remove the pigments effieient and improve sensitivity,suitable for the determination of warfare agents in water and soil.

About this research paper

What this paper is about

In order to rapid deal with the unexpected incidents of chemical agents,a method based on gas chromatography spectrometry(GC/MS) was developed for the determination of nerve warfare agent and vesicant agent simulants in water and soil.The water was extracted by dichloromethane and acetonitrile,the soil was extracted by dichloromethane,then the extract was separated on a HP-5MS column(30 m×0.25 mm×0.25 μm) and the identification and quantification of the analytes were carried out in the choice ion(SIM) mode.The six point calibration curves showed a good linearity for all the congeners(0.998 4~0.999 9).Limits of detection(LODs) of the water ranged from 0.3 to 2.1 μg/L and the soil ranged from 1.0 to 2.7 μg/kg.The relative standard deviations(RSDs) of water and soil were below 11.5%、11.8% respectively.The spiked recoveries of water and soil were in the range of 70.5%~101.9%、70.8%~112.9% respectively.The developed analytical method is rapid and accurate,remove the pigments effieient and improve sensitivity,suitable for the determination of warfare agents in water and soil.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to rapid deal with the unexpected incidents of chemical agents,a method based on gas chromatography spectrometry(GC/MS) was developed for the determination of nerve warfare agent and vesicant agent simulants in water and soil.The water was extracted by dichloromethane and acetonitrile,the soil was extracted by dichloromethane,then the extract was separated on a HP-5MS column(30 m×0.25 mm×0.25 μm) and the identification and quantification of the analytes were carried out in the choice ion(SIM) mode.The six point calibration curves showed a good linearity for all the congeners(0.998 4~0.999 9).Limits of detection(LODs) of the water ranged from 0.3 to 2.1 μg/L and the soil ranged from 1.0 to 2.7 μg/kg.The relative standard deviations(RSDs) of water and soil were below 11.5%、11.8% respectively.The spiked recoveries of water and soil were in the range of 70.5%~101.9%、70.8%~112.9% respectively.The developed analytical method is rapid and accurate,remove the pigments effieient and improve sensitivity,suitable for the determination of warfare agents in water and soil.

Key concepts: Chemistry, Dichloromethane, Chromatography, Detection limit, Calibration curve, Gas chromatography–mass spectrometry, Soil test, Analyte

Related papers

Back to paper searchBrowse research topicsOriginal source
GC/MS Analysis of Chemical Agent Simulants in Water and Soil — Research Paper | ScholarLens