2010•DOAJ (DOAJ: Directory of Open Access Journals)Requires access

Determination of melamine in biscuits by high performance liquid chromatography

Jinmei Wei, Yongmei Zhang, Jiqing Wang, Cao LuXing, Luo Yuzhu

Open publisher page 0 citations

Abstract

A high performance liquid chromatography method was developed for the determination of melamine in biscuits. The biscuit samples were extracted by 1% trichloroacetic acid solution and 2.2% lead acetate, and melamine was separated on a Hypersil ODS C18 column (100 mm×4.6 mm, 5 μm). Acetonitrile and sodium 1-octanesulfonate solution(pH 3) (15∶85, V/V) were used as mobile phase at a flow rate of 1.0 mL·min-1. The detective wavelength was set as 210 nm by an ultraviolet detector. The temperature of column was 40 ℃. The linear ranges for melamine were 0.2-10 μg·mL-1. The average recovery rate of this method varied from 80.5% to 93.5% with the relative standard deviation of 7.7% (n=9) when blank sample was fortified standard working solution of 1, 2 and 4 μg·mL-1.

About this research paper

What this paper is about

A high performance liquid chromatography method was developed for the determination of melamine in biscuits. The biscuit samples were extracted by 1% trichloroacetic acid solution and 2.2% lead acetate, and melamine was separated on a Hypersil ODS C18 column (100 mm×4.6 mm, 5 μm). Acetonitrile and sodium 1-octanesulfonate solution(pH 3) (15∶85, V/V) were used as mobile phase at a flow rate of 1.0 mL·min-1. The detective wavelength was set as 210 nm by an ultraviolet detector. The temperature of column was 40 ℃. The linear ranges for melamine were 0.2-10 μg·mL-1. The average recovery rate of this method varied from 80.5% to 93.5% with the relative standard deviation of 7.7% (n=9) when blank sample was fortified standard working solution of 1, 2 and 4 μg·mL-1.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A high performance liquid chromatography method was developed for the determination of melamine in biscuits. The biscuit samples were extracted by 1% trichloroacetic acid solution and 2.2% lead acetate, and melamine was separated on a Hypersil ODS C18 column (100 mm×4.6 mm, 5 μm). Acetonitrile and sodium 1-octanesulfonate solution(pH 3) (15∶85, V/V) were used as mobile phase at a flow rate of 1.0 mL·min-1. The detective wavelength was set as 210 nm by an ultraviolet detector. The temperature of column was 40 ℃. The linear ranges for melamine were 0.2-10 μg·mL-1. The average recovery rate of this method varied from 80.5% to 93.5% with the relative standard deviation of 7.7% (n=9) when blank sample was fortified standard working solution of 1, 2 and 4 μg·mL-1.

Key concepts: Melamine, Chromatography, Chemistry, High-performance liquid chromatography, Sodium acetate, Relative standard deviation, Acetonitrile, Volumetric flow rate

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of melamine in biscuits by high performance liquid chromatography — Research Paper | ScholarLens