1988Nihon Hotetsu Shika Gakkai ZasshiOpen access

Fundamental studies of impression method. Part 4. Reproducibility of edentulous denture ridge by seating speed and holding pressure of impression tray.

Satoru Yatsu

Open full text 0 citations

Abstract

In this study, the author attempted to explicate the infuluence of thedifference in the impression methods for the simulation models based on the hypothetical pressure-displaceability and the form of the alveolar ridge on the reproducibility of the measuring models.For this purpose, the reproducibility of the master cast were examined by use of the threedimensional position-reproducing apparatus, concerning the two factors the seating speed and the holding pressure of the tray.As a result of this study, the following conclusion was obtained.It has been made clear that the impression of dentulous alveolar ridge (the seating speed and holding pressure of the tray) influences the reproducibility of the simulation model. In the impression of the alveolar ridge possessing normal pressure-displaseability, the reproduceability of the measuring cast was the highest when the measurement was made with the tray atthe seating speed of 100 mm/min, and at the holding pressure of 2.0 kgf. Furthermore, it was suggested that when the tray is pressure-adjusted to the alveolar ridge at a standard or slower seating speed, the tray should be held with great pressure, and when the tray is pressure-adjusted speedily, the tray should be held with little pressure.

Open-access reader

About this research paper

What this paper is about

In this study, the author attempted to explicate the infuluence of thedifference in the impression methods for the simulation models based on the hypothetical pressure-displaceability and the form of the alveolar ridge on the reproducibility of the measuring models.For this purpose, the reproducibility of the master cast were examined by use of the threedimensional position-reproducing apparatus, concerning the two factors the seating speed and the holding pressure of the tray.As a result of this study, the following conclusion was obtained.It has been made clear that the impression of dentulous alveolar ridge (the seating speed and holding pressure of the tray) influences the reproducibility of the simulation model. In the impression of the alveolar ridge possessing normal pressure-displaseability, the reproduceability of the measuring cast was the highest when the measurement was made with the tray atthe seating speed of 100 mm/min, and at the holding pressure of 2.0 kgf. Furthermore, it was suggested that when the tray is pressure-adjusted to the alveolar ridge at a standard or slower seating speed, the tray should be held with great pressure, and when the tray is pressure-adjusted speedily, the tray should be held with little pressure.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this study, the author attempted to explicate the infuluence of thedifference in the impression methods for the simulation models based on the hypothetical pressure-displaceability and the form of the alveolar ridge on the reproducibility of the measuring models.For this purpose, the reproducibility of the master cast were examined by use of the threedimensional position-reproducing apparatus, concerning the two factors the seating speed and the holding pressure of the tray.As a result of this study, the following conclusion was obtained.It has been made clear that the impression of dentulous alveolar ridge (the seating speed and holding pressure of the tray) influences the reproducibility of the simulation model. In the impression of the alveolar ridge possessing normal pressure-displaseability, the reproduceability of the measuring cast was the highest when the measurement was made with the tray atthe seating speed of 100 mm/min, and at the holding pressure of 2.0 kgf. Furthermore, it was suggested that when the tray is pressure-adjusted to the alveolar ridge at a standard or slower seating speed, the tray should be held with great pressure, and when the tray is pressure-adjusted speedily, the tray should be held with little pressure.

Key concepts: Tray, Impression, Reproducibility, Alveolar ridge, Ridge, Orthodontics, Materials science, Mechanical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Fundamental studies of impression method. Part 4. Reproducibility of edentulous denture ridge by seating speed and holding pressure of impression tray. — Research Paper | ScholarLens