2014•Unpublished venueRequires access

The impact analysis of current transformer's saturation to relay protection

Ningting Xu, Dong Jun, Siyuan Zheng

Open publisher page 2 citations

Abstract

This paper gives a full elaboration to the types and fundamentals of the current transformer's saturation, whose impact to all kinds of relay protection device has also been analyzed. Furthermore, an example of a high voltage line's over-grade tripping failure in a substation, which was caused by current transformer's saturation, is dissected. The research of the impact analysis will offer some basis for correctly judging, finding and settling the above mentioned failure in the future.

About this research paper

What this paper is about

This paper gives a full elaboration to the types and fundamentals of the current transformer's saturation, whose impact to all kinds of relay protection device has also been analyzed. Furthermore, an example of a high voltage line's over-grade tripping failure in a substation, which was caused by current transformer's saturation, is dissected. The research of the impact analysis will offer some basis for correctly judging, finding and settling the above mentioned failure in the future.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper gives a full elaboration to the types and fundamentals of the current transformer's saturation, whose impact to all kinds of relay protection device has also been analyzed. Furthermore, an example of a high voltage line's over-grade tripping failure in a substation, which was caused by current transformer's saturation, is dissected. The research of the impact analysis will offer some basis for correctly judging, finding and settling the above mentioned failure in the future.

Key concepts: Tripping, Relay, Current transformer, Transformer, Protective relay, Electrical engineering, Differential protection, Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
The impact analysis of current transformer's saturation to relay protection — Research Paper | ScholarLens