1997BUNSEKI KAGAKUOpen access

Analytical Chemistry in Medical Science and Technology. Determination of methamphethamine by HPLC with chemiluminescence detection.

Kenji Sato, Jyun-ichi OTAKE, Shigeyuki TANAKA

Open full text 3 citations

Abstract

A method is described for the determination of methamphetamine (MP) by a high-performance liquid-chromatographic method using a peroxyoxalate chemiluminescence reaction. After MP was derivatized with 4-(N, N-dimethylaminosulphony1)-7-fluoro-2, 1, 3 benzoxadiazole (DBD-F), it was detected by a chemiluminescence method. Bis(2, 4, 6 trichlorophenyl) oxalate (TCPO) and hydrogen peroxide were used as postcolumn chemiluminescence reagents. The separation of the DBD-F derivative of MP was carried out using a reversed-phase column (GL Science, Lichrospher RP 18-5, 4.6 i.d. × 250 mm) and an acetonitrile aqueous solution as the mobile phase(flow rate, 1.0 ml/min). The optimum pH, temperature and reaction time for fluorogenic reactions of DBD-F and MP were 8, 70°C, 30 min, respectively. The linear calibration graph was observed over the range of 5 × 10-95 ×10-6 M. The correlation coefficient for this line was 0.999. The detection limit (3σ) was 2× 10-9 M (40 fmol) and the relative standard deviation was 1.4% (n=6) for a concentration of 5 × 10-9 M. The effect of urine on the MP determination was investigated. The urine sample solutions were prepared by adding a 1 × 10-7 M or 1 × 10-8 M MP standard solution to a normal human urine. The relative chemiluminescence intensities were 98102% toward the chemiluminescence intensity of the MP standard solution.

Open-access reader

About this research paper

What this paper is about

A method is described for the determination of methamphetamine (MP) by a high-performance liquid-chromatographic method using a peroxyoxalate chemiluminescence reaction. After MP was derivatized with 4-(N, N-dimethylaminosulphony1)-7-fluoro-2, 1, 3 benzoxadiazole (DBD-F), it was detected by a chemiluminescence method. Bis(2, 4, 6 trichlorophenyl) oxalate (TCPO) and hydrogen peroxide were used as postcolumn chemiluminescence reagents. The separation of the DBD-F derivative of MP was carried out using a reversed-phase column (GL Science, Lichrospher RP 18-5, 4.6 i.d. × 250 mm) and an acetonitrile aqueous solution as the mobile phase(flow rate, 1.0 ml/min). The optimum pH, temperature and reaction time for fluorogenic reactions of DBD-F and MP were 8, 70°C, 30 min, respectively. The linear calibration graph was observed over the range of 5 × 10-95 ×10-6 M. The correlation coefficient for this line was 0.999. The detection limit (3σ) was 2× 10-9 M (40 fmol) and the relative standard deviation was 1.4% (n=6) for a concentration of 5 × 10-9 M. The effect of urine on the MP determination was investigated. The urine sample solutions were prepared by adding a 1 × 10-7 M or 1 × 10-8 M MP standard solution to a normal human urine. The relative chemiluminescence intensities were 98102% toward the chemiluminescence intensity of the MP standard solution.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method is described for the determination of methamphetamine (MP) by a high-performance liquid-chromatographic method using a peroxyoxalate chemiluminescence reaction. After MP was derivatized with 4-(N, N-dimethylaminosulphony1)-7-fluoro-2, 1, 3 benzoxadiazole (DBD-F), it was detected by a chemiluminescence method. Bis(2, 4, 6 trichlorophenyl) oxalate (TCPO) and hydrogen peroxide were used as postcolumn chemiluminescence reagents. The separation of the DBD-F derivative of MP was carried out using a reversed-phase column (GL Science, Lichrospher RP 18-5, 4.6 i.d. × 250 mm) and an acetonitrile aqueous solution as the mobile phase(flow rate, 1.0 ml/min). The optimum pH, temperature and reaction time for fluorogenic reactions of DBD-F and MP were 8, 70°C, 30 min, respectively. The linear calibration graph was observed over the range of 5 × 10-95 ×10-6 M. The correlation coefficient for this line was 0.999. The detection limit (3σ) was 2× 10-9 M (40 fmol) and the relative standard deviation was 1.4% (n=6) for a concentration of 5 × 10-9 M. The effect of urine on the MP determination was investigated. The urine sample solutions were prepared by adding a 1 × 10-7 M or 1 × 10-8 M MP standard solution to a normal human urine. The relative chemiluminescence intensities were 98102% toward the chemiluminescence intensity of the MP standard solution.

Key concepts: Chemiluminescence, Peroxyoxalate, Chemistry, Detection limit, Chromatography, Reagent, Oxalate, Hydrogen peroxide

Related papers

Back to paper searchBrowse research topicsOriginal source
Analytical Chemistry in Medical Science and Technology. Determination of methamphethamine by HPLC with chemiluminescence detection. — Research Paper | ScholarLens