High-Performance Liquid Chromatographic Determination of Hydrogen Peroxide with Peroxyoxalate Chemiluminescence Detection
K. Nakashima, M. Wada, Naotaka Kuroda, S. AKIYAMA, Kazuhiro Imai
Abstract
K. Nakashima, M. Wada, Naotaka Kuroda, S. AKIYAMA, Kazuhiro Imai
Abstract
A high performance liquid chromatographic method with peroxyoxalate chemiluminescence (PO-CL) detection was developed for the determination of hydrogen peroxide. Hydrogen peroxide separated by a reversed phase column was detected with the CL produced by the PO-CL reaction using a mixture of 2,4,6,8-tetrathiomorpholi-nopyrimido[5,4-d]pyrimidine and bis[2-(3,6,9-trioxade-cyloxycarbonyl)-4-nitrophenyl]oxalate or bis(2,4,6-trichlorophenyl)oxalate in acetonitrile as a post column reagent. Hydrogen peroxide could be determined over the range of 5–100 pmol on column and the detection limit was 188 fmol at a signal-to-noise ratio of 3. Relative standard deviation of 10-replicate measurements of peak heights for 50 pmol was 2.36%. The detection system applied to the assay of hydrogen peroxide in cola drinks. Trace amounts of hydrogen peroxide could be determined in six cola drinks. The levels were 68.4 ± 2.6–174.2 ± 8.4 nmol/dl. Hydrogen peroxide contaminated in commercially available hydroperoxides was also determined by the proposed method. The amounts obtained were 0.061% for t-butyl hydroper-oxide and 0.003% for cumene hydroperoxide.
OpenAlex reports 45 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A high performance liquid chromatographic method with peroxyoxalate chemiluminescence (PO-CL) detection was developed for the determination of hydrogen peroxide. Hydrogen peroxide separated by a reversed phase column was detected with the CL produced by the PO-CL reaction using a mixture of 2,4,6,8-tetrathiomorpholi-nopyrimido[5,4-d]pyrimidine and bis[2-(3,6,9-trioxade-cyloxycarbonyl)-4-nitrophenyl]oxalate or bis(2,4,6-trichlorophenyl)oxalate in acetonitrile as a post column reagent. Hydrogen peroxide could be determined over the range of 5–100 pmol on column and the detection limit was 188 fmol at a signal-to-noise ratio of 3. Relative standard deviation of 10-replicate measurements of peak heights for 50 pmol was 2.36%. The detection system applied to the assay of hydrogen peroxide in cola drinks. Trace amounts of hydrogen peroxide could be determined in six cola drinks. The levels were 68.4 ± 2.6–174.2 ± 8.4 nmol/dl. Hydrogen peroxide contaminated in commercially available hydroperoxides was also determined by the proposed method. The amounts obtained were 0.061% for t-butyl hydroper-oxide and 0.003% for cumene hydroperoxide.
Key concepts: Peroxyoxalate, Hydrogen peroxide, Chemiluminescence, Chemistry, Oxalate, Detection limit, Chromatography, Reagent