2009Journal of Environmental Engineering (Transactions of AIJ)Open access

FIRE RESISTANCE OF JAPANESE TRADITIONAL TIMBER-FRAME SOIL INTERNAL WALLS EXPOSED TO BOTH-SIDES HEATING

Yoshinao SAWANO, Yuji Hasemi, Noboru Yasui, Atsushi Ogawa, Hiroyuki Hirai, Tadanori Kimura, Kōichi Yamamoto

Open full text 0 citations

Abstract

Mechanical fire resistance of internal load bearing walls under both-sides heating is important for the prevention of collapse of a dwelling in a fire. Feasibility of the 45 minutes mechanical fire resistance with Japanese traditional timber-frame soil internal wall is studied for this purpose. The tests were initiated with intermediate scale specimens for the examination of the charring and internal temperature field of the column and then loaded tests under both-sides exposure were conducted on two 1-story tall bare-timber wall specimens. The tests suggest significant influence of the mortises of columns for horizontal timber bars on the buckling of walls. The conventional predictive method of the mechanical fire resistance of bare timber walls is then modified for the tested configuration.

Open-access reader

About this research paper

What this paper is about

Mechanical fire resistance of internal load bearing walls under both-sides heating is important for the prevention of collapse of a dwelling in a fire. Feasibility of the 45 minutes mechanical fire resistance with Japanese traditional timber-frame soil internal wall is studied for this purpose. The tests were initiated with intermediate scale specimens for the examination of the charring and internal temperature field of the column and then loaded tests under both-sides exposure were conducted on two 1-story tall bare-timber wall specimens. The tests suggest significant influence of the mortises of columns for horizontal timber bars on the buckling of walls. The conventional predictive method of the mechanical fire resistance of bare timber walls is then modified for the tested configuration.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Mechanical fire resistance of internal load bearing walls under both-sides heating is important for the prevention of collapse of a dwelling in a fire. Feasibility of the 45 minutes mechanical fire resistance with Japanese traditional timber-frame soil internal wall is studied for this purpose. The tests were initiated with intermediate scale specimens for the examination of the charring and internal temperature field of the column and then loaded tests under both-sides exposure were conducted on two 1-story tall bare-timber wall specimens. The tests suggest significant influence of the mortises of columns for horizontal timber bars on the buckling of walls. The conventional predictive method of the mechanical fire resistance of bare timber walls is then modified for the tested configuration.

Key concepts: Charring, Fire resistance, Buckling, Structural engineering, Internal forces, Geotechnical engineering, Materials science, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
FIRE RESISTANCE OF JAPANESE TRADITIONAL TIMBER-FRAME SOIL INTERNAL WALLS EXPOSED TO BOTH-SIDES HEATING — Research Paper | ScholarLens