2023Journal of the Chinese Institute of EngineersRequires access

Behavior of fire-retardant treated bolted timber–steel composites (TSCs) and effective charring depth based on experiment

Meng-Ting Tsai, Chien-Pin Kao

Open publisher page 0 citations

Abstract

The bolted joints make timber–steel composites (TSCs) easily to be assembled; however, seams exist between the timber components for bolted TSC components resulting in the risk of fire spreading into the joint seam when the component is under fire. The efficient charring depth provided by timber needs to be clarified; furthermore, the raising temperature potentially affects the strength of steel component. In this study, TSCs were tested in fire for 1 hour, and the following issues were examined, including the experimental charring depth of timber components, the influence of fire-retardant finish in order to provide the efficient charring depth, and additionally the suggested charring depth are proposed for the design of TSCs. In conclusion, the charring depth in the seams was greater than the regulation values, and evaluation methods for the charring depth at seams should be reconsidered. Although the fire-retardant finish reduced the formation rate of the char layer, the flames still breached the seams. The results reveal that Douglas fir TSCs with fire retardant are the most efficient specimen, with effective charring depth 52 mm. While the effective charring depth of Douglas fir TSCs without fire retardant and Japanese Cedar TSCs with fire retardant are increased, at least 64 mm and 65 mm needed, respectively.

About this research paper

What this paper is about

The bolted joints make timber–steel composites (TSCs) easily to be assembled; however, seams exist between the timber components for bolted TSC components resulting in the risk of fire spreading into the joint seam when the component is under fire. The efficient charring depth provided by timber needs to be clarified; furthermore, the raising temperature potentially affects the strength of steel component. In this study, TSCs were tested in fire for 1 hour, and the following issues were examined, including the experimental charring depth of timber components, the influence of fire-retardant finish in order to provide the efficient charring depth, and additionally the suggested charring depth are proposed for the design of TSCs. In conclusion, the charring depth in the seams was greater than the regulation values, and evaluation methods for the charring depth at seams should be reconsidered. Although the fire-retardant finish reduced the formation rate of the char layer, the flames still breached the seams. The results reveal that Douglas fir TSCs with fire retardant are the most efficient specimen, with effective charring depth 52 mm. While the effective charring depth of Douglas fir TSCs without fire retardant and Japanese Cedar TSCs with fire retardant are increased, at least 64 mm and 65 mm needed, respectively.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The bolted joints make timber–steel composites (TSCs) easily to be assembled; however, seams exist between the timber components for bolted TSC components resulting in the risk of fire spreading into the joint seam when the component is under fire. The efficient charring depth provided by timber needs to be clarified; furthermore, the raising temperature potentially affects the strength of steel component. In this study, TSCs were tested in fire for 1 hour, and the following issues were examined, including the experimental charring depth of timber components, the influence of fire-retardant finish in order to provide the efficient charring depth, and additionally the suggested charring depth are proposed for the design of TSCs. In conclusion, the charring depth in the seams was greater than the regulation values, and evaluation methods for the charring depth at seams should be reconsidered. Although the fire-retardant finish reduced the formation rate of the char layer, the flames still breached the seams. The results reveal that Douglas fir TSCs with fire retardant are the most efficient specimen, with effective charring depth 52 mm. While the effective charring depth of Douglas fir TSCs without fire retardant and Japanese Cedar TSCs with fire retardant are increased, at least 64 mm and 65 mm needed, respectively.

Key concepts: Charring, Fire retardant, Char, Materials science, Composite material, Fire performance, Structural engineering, Waste management

Related papers

Back to paper searchBrowse research topicsOriginal source
Behavior of fire-retardant treated bolted timber–steel composites (TSCs) and effective charring depth based on experiment — Research Paper | ScholarLens