1989American Journal of Clinical PathologyRequires access

An Automated Optoelectronic Reticulocyte Counter

Kazuhide Kojima, Masumi Niri, Kazue Setoguchi, Izumi Tsuda, Noriyuki Tatsumi

Open publisher page 43 citations

Abstract

Microscopic reticulocyte counting is time consuming and imprecise. A new reticulocyte counter has been developed, and the authors evaluated its utility for laboratory use. The counter, R-1000 of Sysmex-TOA Medical Electronics Company, Kobe, Japan, is based on the principles of flow cytometry. Reticulocytes are detected as fluorescent cells stained with a basic dye, auramine O, under argon-laser light. The automated count had high correlation to the manual count (r = 0.941). Linearity and reproducibility were both high. About 60 specimens were tested in one hour. Not only the reticulocyte percentage and count but also the maturity of reticulocytes was found from the intensity of the fluorescence, whether high, moderate, or slight. Normal reference values were 0.007 +/- 0.0055 (0.70 +/- 0.55%) for the reticulocytes, (4.63 +/- 1.09) X 10(9)/L for the reticulocyte count, 2.3 +/- 1.9% for highly fluorescent cells, 18.7 +/- 5.1% for moderately fluorescent cells, and 78.8 +/- 6.6% for cells with slight fluorescence. In patients with suppressed bone marrow function, such as is caused by chemotherapy, the reticulocyte fraction and count were low, and cells with slight fluorescence increased. In patients in whom bone marrow function was stimulated, such as with hemolytic anemia, the reticulocyte percentage, reticulocyte count, and highly fluorescent cells were high. Patients with chronic renal failure being treated by hemodialysis had a similar reticulocyte pattern to that in hemolytic anemia except that the reticulocyte count was decreased. Results for elderly patients were not different from those of healthy young controls. Some patients with a normal reticulocyte count and percentage had numerous highly fluorescent cells, perhaps because of hemolytic anemia not yet identified. Automated reticulocyte counting provides reliable data, so such measurement should be useful for analysis of the kinetics of red blood cells and for the study of the pathogenesis of anemia.

About this research paper

What this paper is about

Microscopic reticulocyte counting is time consuming and imprecise. A new reticulocyte counter has been developed, and the authors evaluated its utility for laboratory use. The counter, R-1000 of Sysmex-TOA Medical Electronics Company, Kobe, Japan, is based on the principles of flow cytometry. Reticulocytes are detected as fluorescent cells stained with a basic dye, auramine O, under argon-laser light. The automated count had high correlation to the manual count (r = 0.941). Linearity and reproducibility were both high. About 60 specimens were tested in one hour. Not only the reticulocyte percentage and count but also the maturity of reticulocytes was found from the intensity of the fluorescence, whether high, moderate, or slight. Normal reference values were 0.007 +/- 0.0055 (0.70 +/- 0.55%) for the reticulocytes, (4.63 +/- 1.09) X 10(9)/L for the reticulocyte count, 2.3 +/- 1.9% for highly fluorescent cells, 18.7 +/- 5.1% for moderately fluorescent cells, and 78.8 +/- 6.6% for cells with slight fluorescence. In patients with suppressed bone marrow function, such as is caused by chemotherapy, the reticulocyte fraction and count were low, and cells with slight fluorescence increased. In patients in whom bone marrow function was stimulated, such as with hemolytic anemia, the reticulocyte percentage, reticulocyte count, and highly fluorescent cells were high. Patients with chronic renal failure being treated by hemodialysis had a similar reticulocyte pattern to that in hemolytic anemia except that the reticulocyte count was decreased. Results for elderly patients were not different from those of healthy young controls. Some patients with a normal reticulocyte count and percentage had numerous highly fluorescent cells, perhaps because of hemolytic anemia not yet identified. Automated reticulocyte counting provides reliable data, so such measurement should be useful for analysis of the kinetics of red blood cells and for the study of the pathogenesis of anemia.

Why it matters

OpenAlex reports 43 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Microscopic reticulocyte counting is time consuming and imprecise. A new reticulocyte counter has been developed, and the authors evaluated its utility for laboratory use. The counter, R-1000 of Sysmex-TOA Medical Electronics Company, Kobe, Japan, is based on the principles of flow cytometry. Reticulocytes are detected as fluorescent cells stained with a basic dye, auramine O, under argon-laser light. The automated count had high correlation to the manual count (r = 0.941). Linearity and reproducibility were both high. About 60 specimens were tested in one hour. Not only the reticulocyte percentage and count but also the maturity of reticulocytes was found from the intensity of the fluorescence, whether high, moderate, or slight. Normal reference values were 0.007 +/- 0.0055 (0.70 +/- 0.55%) for the reticulocytes, (4.63 +/- 1.09) X 10(9)/L for the reticulocyte count, 2.3 +/- 1.9% for highly fluorescent cells, 18.7 +/- 5.1% for moderately fluorescent cells, and 78.8 +/- 6.6% for cells with slight fluorescence. In patients with suppressed bone marrow function, such as is caused by chemotherapy, the reticulocyte fraction and count were low, and cells with slight fluorescence increased. In patients in whom bone marrow function was stimulated, such as with hemolytic anemia, the reticulocyte percentage, reticulocyte count, and highly fluorescent cells were high. Patients with chronic renal failure being treated by hemodialysis had a similar reticulocyte pattern to that in hemolytic anemia except that the reticulocyte count was decreased. Results for elderly patients were not different from those of healthy young controls. Some patients with a normal reticulocyte count and percentage had numerous highly fluorescent cells, perhaps because of hemolytic anemia not yet identified. Automated reticulocyte counting provides reliable data, so such measurement should be useful for analysis of the kinetics of red blood cells and for the study of the pathogenesis of anemia.

Key concepts: Reticulocyte, Bone marrow, Flow cytometry, Cytometry, Medicine, Fluorescence, Andrology, Molecular biology

Related papers

Back to paper searchBrowse research topicsOriginal source
An Automated Optoelectronic Reticulocyte Counter — Research Paper | ScholarLens