2014대한건축학회 논문집 - 구조계Requires access

An Experimental Study on 2 Hours Fire Resistance Performance of Load Bearing Walls Used in Modular Buildings

Gap-Deug Kim, Jae-Sung Lee, Seung-Mun Son, Bang-Sub Lee

Open publisher page 5 citations

Abstract

To higher the buildings, fire resistance performance is needed following the purposes and dimensions of the buildings. Especially, two hours fire resistance performance should be satisfied for the buildings above the 4th floor and under the 12th floor. In the case of load bearing walls with steel stud, two hours fire resistance performance have never been recognized in Korea. This study was conducted to investigate two hours fire resistance performance of load bearing walls with steel stud in structural elements of modular buildings. Test specimens in this study were redesigned in the basis of typical load bearing walls used in Europe and North America. The load bearing walls ensuring two hours fire resistance performance were suggested from the test results of this study. The load bearing walls with fireproof board of 45mm thickness secured two hours fire resistance performance in this study.

About this research paper

What this paper is about

To higher the buildings, fire resistance performance is needed following the purposes and dimensions of the buildings. Especially, two hours fire resistance performance should be satisfied for the buildings above the 4th floor and under the 12th floor. In the case of load bearing walls with steel stud, two hours fire resistance performance have never been recognized in Korea. This study was conducted to investigate two hours fire resistance performance of load bearing walls with steel stud in structural elements of modular buildings. Test specimens in this study were redesigned in the basis of typical load bearing walls used in Europe and North America. The load bearing walls ensuring two hours fire resistance performance were suggested from the test results of this study. The load bearing walls with fireproof board of 45mm thickness secured two hours fire resistance performance in this study.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To higher the buildings, fire resistance performance is needed following the purposes and dimensions of the buildings. Especially, two hours fire resistance performance should be satisfied for the buildings above the 4th floor and under the 12th floor. In the case of load bearing walls with steel stud, two hours fire resistance performance have never been recognized in Korea. This study was conducted to investigate two hours fire resistance performance of load bearing walls with steel stud in structural elements of modular buildings. Test specimens in this study were redesigned in the basis of typical load bearing walls used in Europe and North America. The load bearing walls ensuring two hours fire resistance performance were suggested from the test results of this study. The load bearing walls with fireproof board of 45mm thickness secured two hours fire resistance performance in this study.

Key concepts: Fire resistance, Load bearing, Bearing (navigation), Structural engineering, Modular design, Fire performance, Engineering, Resistance (ecology)

Related papers

Back to paper searchBrowse research topicsOriginal source
An Experimental Study on 2 Hours Fire Resistance Performance of Load Bearing Walls Used in Modular Buildings — Research Paper | ScholarLens