2016•RetinaRequires access

WIDE-FIELD INFRARED IMAGING

Vincent Y. Ho, Jarrod Wehmeier, Gaurav Kumar Shah

Open publisher page 20 citations

Abstract

In Brief Purpose: Retinoschisis and retinal detachments are primarily differentiated based on characteristic examination findings. In diagnostically challenging cases, noncontact wide-field infrared imaging can help diagnosis and visualize the extent/margins of retinoschisis, retinal detachment, or combined schisis detachments by comparing reflectivity patterns. Methods: This is a retrospective, observational, descriptive case series of 14 eyes of 14 nonconsecutive patients, ranging from 28 to 89 years old (mean 61), diagnosed with retinoschisis, retinal detachment, or schisis detachment from May 5, 2014 to March 4, 2015. Patients with secondary retinoschisis and/or retinal detachment from other causes were not included in the study. Heidelberg Wide-Field Module lens and Heidelberg Spectralis HRA+OCT machine (Heidelberg Engineering, Heidelberg, Germany) were used to obtain noncontact, wide-field infrared images on each study eye. Results: Seven eyes with retinal detachments, four with retinoschises, and three with schisis detachments were imaged using this novel wide-field infrared technique. Retinoschisis appears light and translucent with prominent vasculature, retinal detachments appear dark and opaque, and combined retinoschisis/retinal detachment exhibit mixed reflectivity patterns. Conclusion: Wide-field infrared imaging provides a quick, noncontact, noninvasive method to accurately diagnose and to monitor for progression of retinoschisis, retinal detachment, or combined schisis detachments. Wide-field infrared imaging provides a quick, noncontact, noninvasive method to accurately diagnose and to monitor for progression of retinoschisis, retinal detachment, or combined schisis detachments. Retinoschisis appears light and translucent with prominent vasculature, retinal detachments appear dark and opaque, and schisis detachments exhibit mixed reflectivity patterns.

About this research paper

What this paper is about

In Brief Purpose: Retinoschisis and retinal detachments are primarily differentiated based on characteristic examination findings. In diagnostically challenging cases, noncontact wide-field infrared imaging can help diagnosis and visualize the extent/margins of retinoschisis, retinal detachment, or combined schisis detachments by comparing reflectivity patterns. Methods: This is a retrospective, observational, descriptive case series of 14 eyes of 14 nonconsecutive patients, ranging from 28 to 89 years old (mean 61), diagnosed with retinoschisis, retinal detachment, or schisis detachment from May 5, 2014 to March 4, 2015. Patients with secondary retinoschisis and/or retinal detachment from other causes were not included in the study. Heidelberg Wide-Field Module lens and Heidelberg Spectralis HRA+OCT machine (Heidelberg Engineering, Heidelberg, Germany) were used to obtain noncontact, wide-field infrared images on each study eye. Results: Seven eyes with retinal detachments, four with retinoschises, and three with schisis detachments were imaged using this novel wide-field infrared technique. Retinoschisis appears light and translucent with prominent vasculature, retinal detachments appear dark and opaque, and combined retinoschisis/retinal detachment exhibit mixed reflectivity patterns. Conclusion: Wide-field infrared imaging provides a quick, noncontact, noninvasive method to accurately diagnose and to monitor for progression of retinoschisis, retinal detachment, or combined schisis detachments. Wide-field infrared imaging provides a quick, noncontact, noninvasive method to accurately diagnose and to monitor for progression of retinoschisis, retinal detachment, or combined schisis detachments. Retinoschisis appears light and translucent with prominent vasculature, retinal detachments appear dark and opaque, and schisis detachments exhibit mixed reflectivity patterns.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In Brief Purpose: Retinoschisis and retinal detachments are primarily differentiated based on characteristic examination findings. In diagnostically challenging cases, noncontact wide-field infrared imaging can help diagnosis and visualize the extent/margins of retinoschisis, retinal detachment, or combined schisis detachments by comparing reflectivity patterns. Methods: This is a retrospective, observational, descriptive case series of 14 eyes of 14 nonconsecutive patients, ranging from 28 to 89 years old (mean 61), diagnosed with retinoschisis, retinal detachment, or schisis detachment from May 5, 2014 to March 4, 2015. Patients with secondary retinoschisis and/or retinal detachment from other causes were not included in the study. Heidelberg Wide-Field Module lens and Heidelberg Spectralis HRA+OCT machine (Heidelberg Engineering, Heidelberg, Germany) were used to obtain noncontact, wide-field infrared images on each study eye. Results: Seven eyes with retinal detachments, four with retinoschises, and three with schisis detachments were imaged using this novel wide-field infrared technique. Retinoschisis appears light and translucent with prominent vasculature, retinal detachments appear dark and opaque, and combined retinoschisis/retinal detachment exhibit mixed reflectivity patterns. Conclusion: Wide-field infrared imaging provides a quick, noncontact, noninvasive method to accurately diagnose and to monitor for progression of retinoschisis, retinal detachment, or combined schisis detachments. Wide-field infrared imaging provides a quick, noncontact, noninvasive method to accurately diagnose and to monitor for progression of retinoschisis, retinal detachment, or combined schisis detachments. Retinoschisis appears light and translucent with prominent vasculature, retinal detachments appear dark and opaque, and schisis detachments exhibit mixed reflectivity patterns.

Key concepts: Retinoschisis, Retinal detachment, Retinal, Ophthalmology, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
WIDE-FIELD INFRARED IMAGING — Research Paper | ScholarLens