Management of Difficult Airway in a Failed Intubation with Videolaryngoscopy in an Infant Patient
A Kuş, Derya Berk, Yavuz Gürkan, Mine Solak, Kamíl Toker
Abstract
Open-access reader
A Kuş, Derya Berk, Yavuz Gürkan, Mine Solak, Kamíl Toker
Abstract
Open-access reader
The videolaryngoscope is a useful alternative airway device for anaesthesia management of difficult airways. However videolaryngoscope intubation may fail due to lack of experience, incorrect application, inappropriate stylet, prior traumatic attempts, restricted cervical movement and limited oropharyngeal airspace. Using a stylet and correctly shaped endotracheal tube is important to facilitate tracheal intubation with the videolaryngoscope, especially in paediatric patients. However, anatomical difficulty in the placement of the laryngoscope blade, association with facial deformities such as micrognathia, having a short neck, cleft palate and being younger than 1 year increase the likelihood of a difficult airway. In this report, we present our approach to difficult airway management in a failed intubation with a videolaryngoscope in an infant undergoing cleft palate surgery.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The videolaryngoscope is a useful alternative airway device for anaesthesia management of difficult airways. However videolaryngoscope intubation may fail due to lack of experience, incorrect application, inappropriate stylet, prior traumatic attempts, restricted cervical movement and limited oropharyngeal airspace. Using a stylet and correctly shaped endotracheal tube is important to facilitate tracheal intubation with the videolaryngoscope, especially in paediatric patients. However, anatomical difficulty in the placement of the laryngoscope blade, association with facial deformities such as micrognathia, having a short neck, cleft palate and being younger than 1 year increase the likelihood of a difficult airway. In this report, we present our approach to difficult airway management in a failed intubation with a videolaryngoscope in an infant undergoing cleft palate surgery.
Key concepts: Stylet, Medicine, Intubation, Airway, Airway management, Endotracheal tube, Anesthesia, Tracheal intubation