2016Tzu Chi Medical JournalOpen access

Comparison between the Trachway video intubating stylet and Macintosh laryngoscope in four simulated difficult tracheal intubations: A manikin study

Jimmy Ong, Chia-Ling Lee, Shen-Jer Huang, Ming‐Hwang Shyr

Open full text 16 citations

Abstract

OBJECTIVES: It remains to be determined whether the TVI-4000 Trachway video intubating (TVI) stylet (Markstein Sichtec Medical Corp, Taichung, Taiwan), an airway device for novices, improves airway management practice by experienced anesthesiologists. The aim of this study was to evaluate the feasibility of using the TVI stylet in difficult tracheal intubation situations compared with that of using the Macintosh laryngoscope on an airway manikin. MATERIALS AND METHODS: Ten anesthesiologists (with 3-21 years' experience), including three senior residents, participated. We compared tracheal intubation in four airway scenarios: normal airway, tongue edema, cervical spine immobilization, and tongue edema combined with cervical spine immobilization. The time of tracheal intubation (TTI), success rate, and perceived difficulty of intubation for each scenario were compared and analyzed. RESULTS: The TTI was significantly shorter in both the tongue edema and combined scenarios with the TVI stylet compared with the Macintosh laryngoscope (21.60 ± 1.45 seconds vs. 24.07 ± 1.58 seconds and 23.73 ± 2.05 seconds vs. 26.6 ± 2.77 seconds, respectively). Success rates for both devices were 100%. Concomitantly, participants rated using the TVI stylet in these two scenarios as being less difficult. CONCLUSION: The learning time for tracheal intubation using the TVI stylet in difficult airway scenarios was short. Use of the TVI stylet was easier and required a shorter TTI for tracheal intubation in the tongue edema and combined scenarios.

Open-access reader

About this research paper

What this paper is about

OBJECTIVES: It remains to be determined whether the TVI-4000 Trachway video intubating (TVI) stylet (Markstein Sichtec Medical Corp, Taichung, Taiwan), an airway device for novices, improves airway management practice by experienced anesthesiologists. The aim of this study was to evaluate the feasibility of using the TVI stylet in difficult tracheal intubation situations compared with that of using the Macintosh laryngoscope on an airway manikin. MATERIALS AND METHODS: Ten anesthesiologists (with 3-21 years' experience), including three senior residents, participated. We compared tracheal intubation in four airway scenarios: normal airway, tongue edema, cervical spine immobilization, and tongue edema combined with cervical spine immobilization. The time of tracheal intubation (TTI), success rate, and perceived difficulty of intubation for each scenario were compared and analyzed. RESULTS: The TTI was significantly shorter in both the tongue edema and combined scenarios with the TVI stylet compared with the Macintosh laryngoscope (21.60 ± 1.45 seconds vs. 24.07 ± 1.58 seconds and 23.73 ± 2.05 seconds vs. 26.6 ± 2.77 seconds, respectively). Success rates for both devices were 100%. Concomitantly, participants rated using the TVI stylet in these two scenarios as being less difficult. CONCLUSION: The learning time for tracheal intubation using the TVI stylet in difficult airway scenarios was short. Use of the TVI stylet was easier and required a shorter TTI for tracheal intubation in the tongue edema and combined scenarios.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVES: It remains to be determined whether the TVI-4000 Trachway video intubating (TVI) stylet (Markstein Sichtec Medical Corp, Taichung, Taiwan), an airway device for novices, improves airway management practice by experienced anesthesiologists. The aim of this study was to evaluate the feasibility of using the TVI stylet in difficult tracheal intubation situations compared with that of using the Macintosh laryngoscope on an airway manikin. MATERIALS AND METHODS: Ten anesthesiologists (with 3-21 years' experience), including three senior residents, participated. We compared tracheal intubation in four airway scenarios: normal airway, tongue edema, cervical spine immobilization, and tongue edema combined with cervical spine immobilization. The time of tracheal intubation (TTI), success rate, and perceived difficulty of intubation for each scenario were compared and analyzed. RESULTS: The TTI was significantly shorter in both the tongue edema and combined scenarios with the TVI stylet compared with the Macintosh laryngoscope (21.60 ± 1.45 seconds vs. 24.07 ± 1.58 seconds and 23.73 ± 2.05 seconds vs. 26.6 ± 2.77 seconds, respectively). Success rates for both devices were 100%. Concomitantly, participants rated using the TVI stylet in these two scenarios as being less difficult. CONCLUSION: The learning time for tracheal intubation using the TVI stylet in difficult airway scenarios was short. Use of the TVI stylet was easier and required a shorter TTI for tracheal intubation in the tongue edema and combined scenarios.

Key concepts: Stylet, Medicine, Video laryngoscope, Anesthesia, Tracheal intubation, Intubation, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison between the Trachway video intubating stylet and Macintosh laryngoscope in four simulated difficult tracheal intubations: A manikin study — Research Paper | ScholarLens