2010Journal of GlaucomaRequires access

Influence of Pupil Dilation on Repeatability of Scanning Laser Polarimetry With Variable and Enhanced Corneal Compensation in Different Stages of Glaucoma

Anita Garas, Márta Tóth, P. Vargha, Gábor Holló

Open publisher page 2 citations

Abstract

PURPOSE: To evaluate the influence of pupil dilation on repeatability of scanning laser polarimetry with variable (GDx-VCC) and enhanced (GDx-ECC) corneal compensation, in different stages of glaucoma. METHODS: One eye of each of 37 Caucasian participants [14 healthy and ocular hypertensive subjects with mean deviation (MD) <2 dB, 11 glaucoma patients with MD 6 to 12 dB, and 12 glaucoma patients with MD >15 dB] was imaged 5 times with both GDx-VCC and GDx-ECC, before and after pupil dilation. RESULTS: No statistically significant alteration was found for any parameter or most coefficients of variation in any group, or in the total study population, due to pupil dilation. Intraclass correlation was similar with both compensation techniques: it varied between 98.5% and 99.2% before, and 97.3% and 99.1% after pupil dilation for all participants. Intrasession variability was below 6 mum for all parameters and all groups irrespective of corneal compensation and pupil dilation. By using GDx-ECC, a statistically significant trend for higher coefficient of variation values in more severe stages of glaucoma was found, irrespective of pupil dilation (Jonckheere-Terpstra test, P<0.026, for all parameters). With GDx-VCC this trend was not seen for 2 of the 3 parameters before pupil dilation, but did appear for all parameters in mydriasis (P<0.002). CONCLUSIONS: Repeatability of GDx-VCC and GDx-ECC is similar, and is satisfactory for clinical purposes; it is only minimally influenced by pharmacological mydriasis. However, repeatability of the measurement decreases with increasing severity of glaucoma. This characteristic is better detectable with GDx-ECC than with GDx-VCC.

About this research paper

What this paper is about

PURPOSE: To evaluate the influence of pupil dilation on repeatability of scanning laser polarimetry with variable (GDx-VCC) and enhanced (GDx-ECC) corneal compensation, in different stages of glaucoma. METHODS: One eye of each of 37 Caucasian participants [14 healthy and ocular hypertensive subjects with mean deviation (MD) <2 dB, 11 glaucoma patients with MD 6 to 12 dB, and 12 glaucoma patients with MD >15 dB] was imaged 5 times with both GDx-VCC and GDx-ECC, before and after pupil dilation. RESULTS: No statistically significant alteration was found for any parameter or most coefficients of variation in any group, or in the total study population, due to pupil dilation. Intraclass correlation was similar with both compensation techniques: it varied between 98.5% and 99.2% before, and 97.3% and 99.1% after pupil dilation for all participants. Intrasession variability was below 6 mum for all parameters and all groups irrespective of corneal compensation and pupil dilation. By using GDx-ECC, a statistically significant trend for higher coefficient of variation values in more severe stages of glaucoma was found, irrespective of pupil dilation (Jonckheere-Terpstra test, P<0.026, for all parameters). With GDx-VCC this trend was not seen for 2 of the 3 parameters before pupil dilation, but did appear for all parameters in mydriasis (P<0.002). CONCLUSIONS: Repeatability of GDx-VCC and GDx-ECC is similar, and is satisfactory for clinical purposes; it is only minimally influenced by pharmacological mydriasis. However, repeatability of the measurement decreases with increasing severity of glaucoma. This characteristic is better detectable with GDx-ECC than with GDx-VCC.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To evaluate the influence of pupil dilation on repeatability of scanning laser polarimetry with variable (GDx-VCC) and enhanced (GDx-ECC) corneal compensation, in different stages of glaucoma. METHODS: One eye of each of 37 Caucasian participants [14 healthy and ocular hypertensive subjects with mean deviation (MD) <2 dB, 11 glaucoma patients with MD 6 to 12 dB, and 12 glaucoma patients with MD >15 dB] was imaged 5 times with both GDx-VCC and GDx-ECC, before and after pupil dilation. RESULTS: No statistically significant alteration was found for any parameter or most coefficients of variation in any group, or in the total study population, due to pupil dilation. Intraclass correlation was similar with both compensation techniques: it varied between 98.5% and 99.2% before, and 97.3% and 99.1% after pupil dilation for all participants. Intrasession variability was below 6 mum for all parameters and all groups irrespective of corneal compensation and pupil dilation. By using GDx-ECC, a statistically significant trend for higher coefficient of variation values in more severe stages of glaucoma was found, irrespective of pupil dilation (Jonckheere-Terpstra test, P<0.026, for all parameters). With GDx-VCC this trend was not seen for 2 of the 3 parameters before pupil dilation, but did appear for all parameters in mydriasis (P<0.002). CONCLUSIONS: Repeatability of GDx-VCC and GDx-ECC is similar, and is satisfactory for clinical purposes; it is only minimally influenced by pharmacological mydriasis. However, repeatability of the measurement decreases with increasing severity of glaucoma. This characteristic is better detectable with GDx-ECC than with GDx-VCC.

Key concepts: Pupillary response, Repeatability, Glaucoma, Scanning laser polarimetry, Mydriasis, Pupil, Ophthalmology, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of Pupil Dilation on Repeatability of Scanning Laser Polarimetry With Variable and Enhanced Corneal Compensation in Different Stages of Glaucoma — Research Paper | ScholarLens