1973Journal of the Japan Society of Precision EngineeringOpen access

Study on the Chip-excluding (1st Report)

Kiyoshi MINATO, Toshio TESHIMA, Yoshiaki KAKINO

Open full text 1 citations

Abstract

An estimating method of the facility of chip-excluding is proposed, and this method is applied to the case of chip-absorbing with air. The following results are obtained from this study : (1) The facility of chip-absorbing with air (time necessary for absorbing a unit volume of chip or the ratio between the weight of absorbed chip and that of total produced chip) is estimated quantitatively by the following “shape coefficient of chip CR” which consists of terms of the maximum length of a chip L (mm), the weight of a chip W (g) and the volumetric coefficient RCR= L+ 17.47 W+4.18 R(2) The capacity of chip-excluding machine, suitability of cutting conditions, etc. can be quantitatively estimated by “shape coefficient of chip CR.”

Open-access reader

About this research paper

What this paper is about

An estimating method of the facility of chip-excluding is proposed, and this method is applied to the case of chip-absorbing with air. The following results are obtained from this study : (1) The facility of chip-absorbing with air (time necessary for absorbing a unit volume of chip or the ratio between the weight of absorbed chip and that of total produced chip) is estimated quantitatively by the following “shape coefficient of chip CR” which consists of terms of the maximum length of a chip L (mm), the weight of a chip W (g) and the volumetric coefficient RCR= L+ 17.47 W+4.18 R(2) The capacity of chip-excluding machine, suitability of cutting conditions, etc. can be quantitatively estimated by “shape coefficient of chip CR.”

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An estimating method of the facility of chip-excluding is proposed, and this method is applied to the case of chip-absorbing with air. The following results are obtained from this study : (1) The facility of chip-absorbing with air (time necessary for absorbing a unit volume of chip or the ratio between the weight of absorbed chip and that of total produced chip) is estimated quantitatively by the following “shape coefficient of chip CR” which consists of terms of the maximum length of a chip L (mm), the weight of a chip W (g) and the volumetric coefficient RCR= L+ 17.47 W+4.18 R(2) The capacity of chip-excluding machine, suitability of cutting conditions, etc. can be quantitatively estimated by “shape coefficient of chip CR.”

Key concepts: Chip, Materials science, Volume (thermodynamics), Silicon chip, Optoelectronics, Physics, Electrical engineering, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the Chip-excluding (1st Report) — Research Paper | ScholarLens