2000Current Opinion in CardiologyRequires access

Noninvasive assessment of hemodynamics: an emphasis on bioimpedance cardiography

Paul B. Rosenberg, Clyde W. Yancy

Open publisher page 54 citations

Abstract

Evaluation of the hemodynamic response in heart failure is a useful adjunct in clinical management. Invasive monitoring has been the accepted gold standard of hemodynamic assessment but carries with it significant associated risks. Noninvasive hemodynamic assessment in heart failure previously has been either unreliable or difficult to obtain. Bioimpedance relies on the proportional change in the conduction of alternating current applied across the thorax as a function of blood volume in the heart and great vessels. Stroke volume, cardiac output, thoracic fluid content, and measures of diastolic function can be determined with bioimpedance. Impedance cardiography is becoming an accepted method for safe, reliable, and reproducible assessment of hemodynamics in heart failure.

About this research paper

What this paper is about

Evaluation of the hemodynamic response in heart failure is a useful adjunct in clinical management. Invasive monitoring has been the accepted gold standard of hemodynamic assessment but carries with it significant associated risks. Noninvasive hemodynamic assessment in heart failure previously has been either unreliable or difficult to obtain. Bioimpedance relies on the proportional change in the conduction of alternating current applied across the thorax as a function of blood volume in the heart and great vessels. Stroke volume, cardiac output, thoracic fluid content, and measures of diastolic function can be determined with bioimpedance. Impedance cardiography is becoming an accepted method for safe, reliable, and reproducible assessment of hemodynamics in heart failure.

Why it matters

OpenAlex reports 54 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Evaluation of the hemodynamic response in heart failure is a useful adjunct in clinical management. Invasive monitoring has been the accepted gold standard of hemodynamic assessment but carries with it significant associated risks. Noninvasive hemodynamic assessment in heart failure previously has been either unreliable or difficult to obtain. Bioimpedance relies on the proportional change in the conduction of alternating current applied across the thorax as a function of blood volume in the heart and great vessels. Stroke volume, cardiac output, thoracic fluid content, and measures of diastolic function can be determined with bioimpedance. Impedance cardiography is becoming an accepted method for safe, reliable, and reproducible assessment of hemodynamics in heart failure.

Key concepts: Impedance cardiography, Medicine, Hemodynamics, Stroke volume, Heart failure, Cardiac output, Cardiology, Cardiac function curve

Related papers

Back to paper searchBrowse research topicsOriginal source
Noninvasive assessment of hemodynamics: an emphasis on bioimpedance cardiography — Research Paper | ScholarLens