Measurement of cardiac stroke volume by impedance cardiography in the last trimester of pregnancy

Ian Milsom, Lars Forssman, Ramon Sivertsson, O. Dottori

Open publisher page 56 citations

Abstract

Simultaneous determination of cardiac stroke volume by impedance cardiography and the dye dilution technique was compared in 10 women during the last trimester of pregnancy. Measurements were performed in different body positions to investigate the influence of body position on stroke volume. The correlation coefficient for all measurements was 0.87. Mean stroke volume determined by impedance cardiography was significantly (p less than 001) lower than mean stroke volume calculated by the dye dilution technique. There was no significant difference between the mean change in stroke volume determined by the two techniques during serial measurements. The reproducibility of individual impedance-determined stroke volumes (6.1 ml) did not differ significantly from individual values obtained by dye dilution (9.3 ml). Maximum mean impedance-determined stroke volume was recorded in the left lateral position (83.8 +/- 4.0 ml). Mean stroke volume was significantly (p less than 0.01) reduced in the supine position (17.9%). A smaller (14.4%) reduction was registered in the right lateral position. These changes in stroke volume according to body position were equally evident by both methods. Impedance cardiography is a safe, reliable, non-invasive technique for the measurement of changes in stroke volume during late pregnancy. The ability of impedance cardiography to determine changes in stroke volume was unaffected by changes in body position.

About this research paper

What this paper is about

Simultaneous determination of cardiac stroke volume by impedance cardiography and the dye dilution technique was compared in 10 women during the last trimester of pregnancy. Measurements were performed in different body positions to investigate the influence of body position on stroke volume. The correlation coefficient for all measurements was 0.87. Mean stroke volume determined by impedance cardiography was significantly (p less than 001) lower than mean stroke volume calculated by the dye dilution technique. There was no significant difference between the mean change in stroke volume determined by the two techniques during serial measurements. The reproducibility of individual impedance-determined stroke volumes (6.1 ml) did not differ significantly from individual values obtained by dye dilution (9.3 ml). Maximum mean impedance-determined stroke volume was recorded in the left lateral position (83.8 +/- 4.0 ml). Mean stroke volume was significantly (p less than 0.01) reduced in the supine position (17.9%). A smaller (14.4%) reduction was registered in the right lateral position. These changes in stroke volume according to body position were equally evident by both methods. Impedance cardiography is a safe, reliable, non-invasive technique for the measurement of changes in stroke volume during late pregnancy. The ability of impedance cardiography to determine changes in stroke volume was unaffected by changes in body position.

Why it matters

OpenAlex reports 56 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Simultaneous determination of cardiac stroke volume by impedance cardiography and the dye dilution technique was compared in 10 women during the last trimester of pregnancy. Measurements were performed in different body positions to investigate the influence of body position on stroke volume. The correlation coefficient for all measurements was 0.87. Mean stroke volume determined by impedance cardiography was significantly (p less than 001) lower than mean stroke volume calculated by the dye dilution technique. There was no significant difference between the mean change in stroke volume determined by the two techniques during serial measurements. The reproducibility of individual impedance-determined stroke volumes (6.1 ml) did not differ significantly from individual values obtained by dye dilution (9.3 ml). Maximum mean impedance-determined stroke volume was recorded in the left lateral position (83.8 +/- 4.0 ml). Mean stroke volume was significantly (p less than 0.01) reduced in the supine position (17.9%). A smaller (14.4%) reduction was registered in the right lateral position. These changes in stroke volume according to body position were equally evident by both methods. Impedance cardiography is a safe, reliable, non-invasive technique for the measurement of changes in stroke volume during late pregnancy. The ability of impedance cardiography to determine changes in stroke volume was unaffected by changes in body position.

Key concepts: Impedance cardiography, Medicine, Stroke volume, Pregnancy, First trimester, Stroke (engine), Cardiology, Obstetrics

Related papers

Back to paper searchBrowse research topicsOriginal source
Measurement of cardiac stroke volume by impedance cardiography in the last trimester of pregnancy — Research Paper | ScholarLens