2011Aviation Space and Environmental MedicineRequires access

Characterization of Airway Device Cuff Volumes at Simulated Altitude

Jennifer Law, Aaron E. Bair, Jason Capra, A.D. Holder, Robert William Allen

Open publisher page 6 citations

Abstract

INTRODUCTION: Cuff volume of an air-filled airway device varies inversely with ambient pressure at altitude. This may result in problems with ventilation, aspiration, and tissue ischemia in intubated patients transported by aircraft. We aimed to characterize cuff volume changes in airway devices as a function of altitude. METHODS: Four inflatable airway devices lendotracheal tube (ETT), Combitube, King tube, and laryngeal mask airway (LMA)I, each inflated with air or water, were evaluated for cuff volume changes in an altitude chamber simulating ascent and descent from ground level to 15,000 ft (4572 m). A novel cuff-less supraglottic device called i-gel was also tested. Multivariate linear regression was used to assess the effect of altitude and cuff content on cuff volume. RESULTS: We found a linear relationship between air-filled cuff volume and altitude in all the inflatable airway devices. The Combitube (correlation coefficient R = 0.94) and King tube (R = 0.98) showed the clearest linear relationship; the ETT (R = 0.70) and LMA (0.86) showed modest correlations. With water-filled cuffs, the rate of increase was relatively smaller in all the inflatable devices except the ETT, which remained constant. The difference between air- and water-filled cuffs was statistically significant in each inflatable device (P < 0.001). The i-gel showed no volume change at any of the tested altitudes. CONCLUSIONS: Cuff volume of inflatable airway devices increased linearly with altitude. The dual-cuffed supraglottic devices showed greater volume changes, likely due to the combined effect of their two cuffs. Of the inflatable devices, the water-filled ETT was the least sensitive to altitude changes.

About this research paper

What this paper is about

INTRODUCTION: Cuff volume of an air-filled airway device varies inversely with ambient pressure at altitude. This may result in problems with ventilation, aspiration, and tissue ischemia in intubated patients transported by aircraft. We aimed to characterize cuff volume changes in airway devices as a function of altitude. METHODS: Four inflatable airway devices lendotracheal tube (ETT), Combitube, King tube, and laryngeal mask airway (LMA)I, each inflated with air or water, were evaluated for cuff volume changes in an altitude chamber simulating ascent and descent from ground level to 15,000 ft (4572 m). A novel cuff-less supraglottic device called i-gel was also tested. Multivariate linear regression was used to assess the effect of altitude and cuff content on cuff volume. RESULTS: We found a linear relationship between air-filled cuff volume and altitude in all the inflatable airway devices. The Combitube (correlation coefficient R = 0.94) and King tube (R = 0.98) showed the clearest linear relationship; the ETT (R = 0.70) and LMA (0.86) showed modest correlations. With water-filled cuffs, the rate of increase was relatively smaller in all the inflatable devices except the ETT, which remained constant. The difference between air- and water-filled cuffs was statistically significant in each inflatable device (P < 0.001). The i-gel showed no volume change at any of the tested altitudes. CONCLUSIONS: Cuff volume of inflatable airway devices increased linearly with altitude. The dual-cuffed supraglottic devices showed greater volume changes, likely due to the combined effect of their two cuffs. Of the inflatable devices, the water-filled ETT was the least sensitive to altitude changes.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

INTRODUCTION: Cuff volume of an air-filled airway device varies inversely with ambient pressure at altitude. This may result in problems with ventilation, aspiration, and tissue ischemia in intubated patients transported by aircraft. We aimed to characterize cuff volume changes in airway devices as a function of altitude. METHODS: Four inflatable airway devices lendotracheal tube (ETT), Combitube, King tube, and laryngeal mask airway (LMA)I, each inflated with air or water, were evaluated for cuff volume changes in an altitude chamber simulating ascent and descent from ground level to 15,000 ft (4572 m). A novel cuff-less supraglottic device called i-gel was also tested. Multivariate linear regression was used to assess the effect of altitude and cuff content on cuff volume. RESULTS: We found a linear relationship between air-filled cuff volume and altitude in all the inflatable airway devices. The Combitube (correlation coefficient R = 0.94) and King tube (R = 0.98) showed the clearest linear relationship; the ETT (R = 0.70) and LMA (0.86) showed modest correlations. With water-filled cuffs, the rate of increase was relatively smaller in all the inflatable devices except the ETT, which remained constant. The difference between air- and water-filled cuffs was statistically significant in each inflatable device (P < 0.001). The i-gel showed no volume change at any of the tested altitudes. CONCLUSIONS: Cuff volume of inflatable airway devices increased linearly with altitude. The dual-cuffed supraglottic devices showed greater volume changes, likely due to the combined effect of their two cuffs. Of the inflatable devices, the water-filled ETT was the least sensitive to altitude changes.

Key concepts: Inflatable, Cuff, Airway, Effects of high altitude on humans, Altitude (triangle), Volume (thermodynamics), Medicine, Ventilation (architecture)