2016Nuclear Medicine CommunicationsRequires access

Fractionated elution using the TEKCIS technetium-99m generator

Jonathan Vigne, Rémy De Mil, Damien Peyronnet, C. Hecquard, Denis Agostini, F. Lemonnier

Open publisher page 1 citations

Abstract

The TEKCIS technetium-99m (Tc) generator was designed to allow dry column shipment and automatized conception. A high Tc radioactive concentration is required in a subset of radiopharmacy procedures. Fractionated elution can be a useful tool to meet this requirement, especially when current elution is close to the generator expiration date. The aim of our study was to assess TEKCIS generator elution kinetics and to determine the optimal fractionated elution time to fit with procedures requiring the highest Tc radioactive concentration in clinical use. After duplicate elution at several predetermined elution times, the volume and activity of each eluate were measured. Two optimal time points were selected to perform fractionated elution and repeatability (n=34 and 33) assessed on TEKCIS generators calibrated at 6 or 8 GBq. The complete eluate volume (5 ml) was collected after 60 s of elution. A logarithmic equation was established between eluate volume (v, ml) from elapsed elution time (t, s): v=1.8335ln(t)-2.5965. Using the reciprocal equation, elution times required to obtain some commonly eluted volumes were calculated. Fractionated elutions during 15 and 20 s were selected and an average elution volume from 2.74 to 3.27 ml was collected, with an average elution yield of approximately 90 and 100%, respectively. Our work provides a simple and reliable methodology for the use of fractionated elution with the new TEKCIS generator.

About this research paper

What this paper is about

The TEKCIS technetium-99m (Tc) generator was designed to allow dry column shipment and automatized conception. A high Tc radioactive concentration is required in a subset of radiopharmacy procedures. Fractionated elution can be a useful tool to meet this requirement, especially when current elution is close to the generator expiration date. The aim of our study was to assess TEKCIS generator elution kinetics and to determine the optimal fractionated elution time to fit with procedures requiring the highest Tc radioactive concentration in clinical use. After duplicate elution at several predetermined elution times, the volume and activity of each eluate were measured. Two optimal time points were selected to perform fractionated elution and repeatability (n=34 and 33) assessed on TEKCIS generators calibrated at 6 or 8 GBq. The complete eluate volume (5 ml) was collected after 60 s of elution. A logarithmic equation was established between eluate volume (v, ml) from elapsed elution time (t, s): v=1.8335ln(t)-2.5965. Using the reciprocal equation, elution times required to obtain some commonly eluted volumes were calculated. Fractionated elutions during 15 and 20 s were selected and an average elution volume from 2.74 to 3.27 ml was collected, with an average elution yield of approximately 90 and 100%, respectively. Our work provides a simple and reliable methodology for the use of fractionated elution with the new TEKCIS generator.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The TEKCIS technetium-99m (Tc) generator was designed to allow dry column shipment and automatized conception. A high Tc radioactive concentration is required in a subset of radiopharmacy procedures. Fractionated elution can be a useful tool to meet this requirement, especially when current elution is close to the generator expiration date. The aim of our study was to assess TEKCIS generator elution kinetics and to determine the optimal fractionated elution time to fit with procedures requiring the highest Tc radioactive concentration in clinical use. After duplicate elution at several predetermined elution times, the volume and activity of each eluate were measured. Two optimal time points were selected to perform fractionated elution and repeatability (n=34 and 33) assessed on TEKCIS generators calibrated at 6 or 8 GBq. The complete eluate volume (5 ml) was collected after 60 s of elution. A logarithmic equation was established between eluate volume (v, ml) from elapsed elution time (t, s): v=1.8335ln(t)-2.5965. Using the reciprocal equation, elution times required to obtain some commonly eluted volumes were calculated. Fractionated elutions during 15 and 20 s were selected and an average elution volume from 2.74 to 3.27 ml was collected, with an average elution yield of approximately 90 and 100%, respectively. Our work provides a simple and reliable methodology for the use of fractionated elution with the new TEKCIS generator.

Key concepts: Elution, Chromatography, Repeatability, Chemistry, Generator (circuit theory), Volume (thermodynamics), Quantum mechanics, Power (physics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Fractionated elution using the TEKCIS technetium-99m generator — Research Paper | ScholarLens