Intra‐ and interday repeatability of peripheral arterial function: suitability and potential limitations
Cristian Del Bo’, Valeria Deon, Marisa Porrini, Jonica Campolo, Marina Parolini, Patrizia Riso
Abstract
Cristian Del Bo’, Valeria Deon, Marisa Porrini, Jonica Campolo, Marina Parolini, Patrizia Riso
Abstract
OBJECTIVE: This study aimed to investigate the inter-and intraday repeatability of RHI measured by Endo-PAT in healthy volunteers. METHODS: Interday RHI repeatability was tested in two consecutive days in a group of 31 male subjects. Intraday repeatability was investigated at baseline and after 2 and 4 hour in a group of 16 volunteers. Data were evaluated by analysis of variance. Bland-Altman plot, CV, CR, and ICC were measured. RESULTS: While interday RHI repeatability was found to be reliable (CV: 6.0%; CR: 0.51; ICC: 0.77), multiple evaluations within the same day significantly (P<.001) affected RHI (repeatability of the measurement -CV: 18.8%; CR: 1.26; ICC: 0.48). In particular, a significant increase in RHI occurred at 4 hour compared to 2 hour (+16.8%; P<.05) and to baseline (+30.1%; P<.05). CONCLUSIONS: RHI showed good interday but poor intraday repeatability. Multiple evaluations increased RHI especially in subjects with endothelial dysfunction who improved or reversed their impairment. These results show the potential limitations of multiple Endo-PAT measurements within the same day and the importance of standardizing the protocols before RHI evaluations.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: This study aimed to investigate the inter-and intraday repeatability of RHI measured by Endo-PAT in healthy volunteers. METHODS: Interday RHI repeatability was tested in two consecutive days in a group of 31 male subjects. Intraday repeatability was investigated at baseline and after 2 and 4 hour in a group of 16 volunteers. Data were evaluated by analysis of variance. Bland-Altman plot, CV, CR, and ICC were measured. RESULTS: While interday RHI repeatability was found to be reliable (CV: 6.0%; CR: 0.51; ICC: 0.77), multiple evaluations within the same day significantly (P<.001) affected RHI (repeatability of the measurement -CV: 18.8%; CR: 1.26; ICC: 0.48). In particular, a significant increase in RHI occurred at 4 hour compared to 2 hour (+16.8%; P<.05) and to baseline (+30.1%; P<.05). CONCLUSIONS: RHI showed good interday but poor intraday repeatability. Multiple evaluations increased RHI especially in subjects with endothelial dysfunction who improved or reversed their impairment. These results show the potential limitations of multiple Endo-PAT measurements within the same day and the importance of standardizing the protocols before RHI evaluations.
Key concepts: Repeatability, Peripheral, Function (biology), Medicine, Cardiology, Internal medicine, Chemistry, Biology