2016MicrocirculationOpen access

Intra‐ and interday repeatability of peripheral arterial function: suitability and potential limitations

Cristian Del Bo’, Valeria Deon, Marisa Porrini, Jonica Campolo, Marina Parolini, Patrizia Riso

Open full text 4 citations

Abstract

OBJECTIVE: This study aimed to investigate the inter-and intraday repeatability of RHI measured by Endo-PAT in healthy volunteers. METHODS: Interday RHI repeatability was tested in two consecutive days in a group of 31 male subjects. Intraday repeatability was investigated at baseline and after 2 and 4 hour in a group of 16 volunteers. Data were evaluated by analysis of variance. Bland-Altman plot, CV, CR, and ICC were measured. RESULTS: While interday RHI repeatability was found to be reliable (CV: 6.0%; CR: 0.51; ICC: 0.77), multiple evaluations within the same day significantly (P<.001) affected RHI (repeatability of the measurement -CV: 18.8%; CR: 1.26; ICC: 0.48). In particular, a significant increase in RHI occurred at 4 hour compared to 2 hour (+16.8%; P<.05) and to baseline (+30.1%; P<.05). CONCLUSIONS: RHI showed good interday but poor intraday repeatability. Multiple evaluations increased RHI especially in subjects with endothelial dysfunction who improved or reversed their impairment. These results show the potential limitations of multiple Endo-PAT measurements within the same day and the importance of standardizing the protocols before RHI evaluations.

About this research paper

What this paper is about

OBJECTIVE: This study aimed to investigate the inter-and intraday repeatability of RHI measured by Endo-PAT in healthy volunteers. METHODS: Interday RHI repeatability was tested in two consecutive days in a group of 31 male subjects. Intraday repeatability was investigated at baseline and after 2 and 4 hour in a group of 16 volunteers. Data were evaluated by analysis of variance. Bland-Altman plot, CV, CR, and ICC were measured. RESULTS: While interday RHI repeatability was found to be reliable (CV: 6.0%; CR: 0.51; ICC: 0.77), multiple evaluations within the same day significantly (P<.001) affected RHI (repeatability of the measurement -CV: 18.8%; CR: 1.26; ICC: 0.48). In particular, a significant increase in RHI occurred at 4 hour compared to 2 hour (+16.8%; P<.05) and to baseline (+30.1%; P<.05). CONCLUSIONS: RHI showed good interday but poor intraday repeatability. Multiple evaluations increased RHI especially in subjects with endothelial dysfunction who improved or reversed their impairment. These results show the potential limitations of multiple Endo-PAT measurements within the same day and the importance of standardizing the protocols before RHI evaluations.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: This study aimed to investigate the inter-and intraday repeatability of RHI measured by Endo-PAT in healthy volunteers. METHODS: Interday RHI repeatability was tested in two consecutive days in a group of 31 male subjects. Intraday repeatability was investigated at baseline and after 2 and 4 hour in a group of 16 volunteers. Data were evaluated by analysis of variance. Bland-Altman plot, CV, CR, and ICC were measured. RESULTS: While interday RHI repeatability was found to be reliable (CV: 6.0%; CR: 0.51; ICC: 0.77), multiple evaluations within the same day significantly (P<.001) affected RHI (repeatability of the measurement -CV: 18.8%; CR: 1.26; ICC: 0.48). In particular, a significant increase in RHI occurred at 4 hour compared to 2 hour (+16.8%; P<.05) and to baseline (+30.1%; P<.05). CONCLUSIONS: RHI showed good interday but poor intraday repeatability. Multiple evaluations increased RHI especially in subjects with endothelial dysfunction who improved or reversed their impairment. These results show the potential limitations of multiple Endo-PAT measurements within the same day and the importance of standardizing the protocols before RHI evaluations.

Key concepts: Repeatability, Peripheral, Function (biology), Medicine, Cardiology, Internal medicine, Chemistry, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Intra‐ and interday repeatability of peripheral arterial function: suitability and potential limitations — Research Paper | ScholarLens