Diabetes bearer: evaluation of insulin self-application
Tatiane Gomes Guedes, Fernanda Celedonio de Oliveira, Maria Albertína Rocha Diógenes, Cleide Ferreira Damasceno
Abstract
Tatiane Gomes Guedes, Fernanda Celedonio de Oliveira, Maria Albertína Rocha Diógenes, Cleide Ferreira Damasceno
Abstract
The study aimed at analyzing the self-application of insulin by bearers of diabetes type 2, in a unit of Diabetes and Hypertension reference center, in Fortaleza-CE. It is an exploratory-descriptive study, developed with 80 patients, from January to March, in 2004. The data were collected through semi-structured interviews and analyzed in the computer program Epi-Info 6.0. The results showed that 67 (83.8 %) participants considered the therapy with insulin to be important. As to the technique of application, 30 (37.5 %) do not make the asepsis of the bottle before aspirating and 42 (52.5%) shake the bottle vigorously in order to make the insulin homogeneous. The syringe is re-used by 73 (91.3 %) of the patients. As to the insulin’s storage, 19 (23.8 %) keep it correctly. The turnover of applications is done only by 5 (6.3 %) of the patients. It has been noticed that there are incorrect aspects in the insulin’s usage. A better education in health is proposed, in order to contribute to the selfsufficiency and the enhancement of the Diabetes mellitus bearer’s quality of life.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The study aimed at analyzing the self-application of insulin by bearers of diabetes type 2, in a unit of Diabetes and Hypertension reference center, in Fortaleza-CE. It is an exploratory-descriptive study, developed with 80 patients, from January to March, in 2004. The data were collected through semi-structured interviews and analyzed in the computer program Epi-Info 6.0. The results showed that 67 (83.8 %) participants considered the therapy with insulin to be important. As to the technique of application, 30 (37.5 %) do not make the asepsis of the bottle before aspirating and 42 (52.5%) shake the bottle vigorously in order to make the insulin homogeneous. The syringe is re-used by 73 (91.3 %) of the patients. As to the insulin’s storage, 19 (23.8 %) keep it correctly. The turnover of applications is done only by 5 (6.3 %) of the patients. It has been noticed that there are incorrect aspects in the insulin’s usage. A better education in health is proposed, in order to contribute to the selfsufficiency and the enhancement of the Diabetes mellitus bearer’s quality of life.
Key concepts: Insulin, Diabetes mellitus, Medicine, Syringe, Insulin pen, Asepsis, Bottle, Internal medicine