The intra- and inter-day reproducibility of the FitroDyne as a measure of multi-jointed muscle function
John F. T. Fernandes, Kevin Lamb, Craig Twist
Abstract
John F. T. Fernandes, Kevin Lamb, Craig Twist
Abstract
BACKGROUND: The FitroDyne has been used to assess muscle function but its reproducibility has not been determined during traditional multi-jointed resistance exercises. OBJECTIVE: To assess the intra- and inter-day reproducibility of the FitroDyne during traditional resistance exercises. METHODS: Fourteen resistance trained males completed a one repetition maximum (1RM) and three repetitions of bench press, squat and bent-over-row in 10% increments (from 20 to 80%). Replica trials were completed two and 48 hours later. The FitroDyne rotary encoder measured barbell velocity during each repetition from which power output was calculated. RESULTS: For all loads and exercises the intra-day typical error (TE) for peak and mean power, and velocity, respectively, during bench press (8.2-53 W and 2.2-6.9 cm ⋅ s - 1 ), squat (13.3-55.6 W and 2.4-7.4 cm ⋅ s - 1 ), and bent-over-row(14.5-62.8 W and 4-10.5 cm ⋅ s - 1 ) identified only moderate changes. Bench press yielded poor intra-day reproducibility at 80% 1RM only (CV% = 12.2-17.1), whereas squat and bent-over-row across all loads for peak and mean power and velocity displayed better reproducibility CV% = 2.4-9.0). Inter-day, the TE detected moderate changes for peak and mean power and velocity for all three exercises. Inter-day reproducibility was comparable to intra-day, though improved for bench press 80% 1RM (CV% = 6.1-8.6). CONCLUSION: These data support the use of the FitroDyne at submaximal loads for monitoring moderate changes in muscle function both intra- and inter-day.
OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
BACKGROUND: The FitroDyne has been used to assess muscle function but its reproducibility has not been determined during traditional multi-jointed resistance exercises. OBJECTIVE: To assess the intra- and inter-day reproducibility of the FitroDyne during traditional resistance exercises. METHODS: Fourteen resistance trained males completed a one repetition maximum (1RM) and three repetitions of bench press, squat and bent-over-row in 10% increments (from 20 to 80%). Replica trials were completed two and 48 hours later. The FitroDyne rotary encoder measured barbell velocity during each repetition from which power output was calculated. RESULTS: For all loads and exercises the intra-day typical error (TE) for peak and mean power, and velocity, respectively, during bench press (8.2-53 W and 2.2-6.9 cm ⋅ s - 1 ), squat (13.3-55.6 W and 2.4-7.4 cm ⋅ s - 1 ), and bent-over-row(14.5-62.8 W and 4-10.5 cm ⋅ s - 1 ) identified only moderate changes. Bench press yielded poor intra-day reproducibility at 80% 1RM only (CV% = 12.2-17.1), whereas squat and bent-over-row across all loads for peak and mean power and velocity displayed better reproducibility CV% = 2.4-9.0). Inter-day, the TE detected moderate changes for peak and mean power and velocity for all three exercises. Inter-day reproducibility was comparable to intra-day, though improved for bench press 80% 1RM (CV% = 6.1-8.6). CONCLUSION: These data support the use of the FitroDyne at submaximal loads for monitoring moderate changes in muscle function both intra- and inter-day.
Key concepts: Reproducibility, Bench press, Squat, One-repetition maximum, Mathematics, Muscle power, Resistance training, Biomedical engineering